Unit Operation.

Shown below is the 'CSC15' Controller which regulates the operation of the Unit. Unit Status LEDs, Hour Meter,
and ON/OFF switch are located on the control panel cover.
Starting the Unit:
Stopping the Unit:
Note:
1. Do not stop the Unit by use of a disconnect or breaker.
Using the disconnect, or breaker to stop the Unit will not allow the Unit to go
through an unloading sequence, and could result in damage to the Motor, Starter,
or other electrical components. Damage caused in this manner is not covered by
the manufacturers Warranty.
Hour Meter.
Displays the number of
running hours.
Start / Stop Switch
ON position:
Starts compressor
OFF position:
Compressor unloads for 10
seconds and then stops
Quick Start (cont'd)
Turn the Selector Switch to 'ON' position.
Turn the Switch to 'OFF' position, unit will unload for 10 seconds prior to stopping.
Fault Light.
Compressor fault indicator:
ON Solid =
Fast Flash =
Two Flashes =
Three Flashes = Overload Fault
*Depress 'Reset' button within
cabinet to clear fault.
- 3 -
Sep '15
Power Light.
Turns on when power
has been applied to the
unit.
Anti-Rotation
Power Interruption
Service Due*
A5-C