Dyna SD 60 Manual do operador - Página 4
Procurar online ou descarregar pdf Manual do operador para Cortador Dyna SD 60. Dyna SD 60 9 páginas. Tenon cutter
Do a momentary start/stop operation to detect cutter rotation.
Facing the cutter head opening, it should rotate counterclockwise.
The cutter head is screwed on the shaft with right hand threads. It
can be tightened or loosened and removed with pipe wrenches. It
should be checked daily for tightness.
AIR SUPPLY
The air supply MUST be clean and dry for proper performance of
this machine. A commercial air filter and dryer must be put in line
before this machine to protect it from contaminants. Failure to do
so will void the warranty of this machine.
The main inlet air pressure should be between 100 to 125 PSI.
The primary regulator should be set at a minimum of 60 PSI and
the secondary regulator should be set at approximately 80 PSI. The
primary regulator adjusts clamp the pressure for the while the
secondary regulator adjusts the feed cylinder pressure. See Fig. 1.
4