Gage Bilt GB2581-750 Manual - Página 5
Procurar online ou descarregar pdf Manual para Ferramenta eléctrica Gage Bilt GB2581-750. Gage Bilt GB2581-750 10 páginas.
DESCRIPTION
WARNING:
THE BALANCE OF THIS TOOL IS DESIGNED FOR HORIZONTAL USE AND IS NOT SUITED FOR
ANY OTHER APPLICATIONS. GAGE BILT WILL BE PLEASED TO ADVISE FOR YOUR SPECIFIC
APPLICATION.
The GB2581-750 is a hydraulic installation tool. It weighs 6 lbs. 10 oz. (3.0 kg). It has a .750" (19mm) rivet
setting stroke and a rated pull load of 10,700 lbs (47.59kN) @ 7,400 psi. (510.2 bar).
Normal operating pressure is set at 7,400 psi. (510.2 bar) PULL pressure and 3,200 psi. (220.6 bar) RETURN
pressure, enabling the tool to pull all the fasteners listed on the selection chart without adjusting pressures.
Powerunit may be set to the pressures only needed to pull your specific fastener using 942280 pressure
setting gauge. The tool comes equipped with 12' hoses and electric cord kit complete with quick
disconnects.
NOSE ASSEMBLIES ARE NOT FURNISHED WITH THE TOOL AND MUST BE ORDERED SEPARATELY.
MAINTENANCE
WARNING:
EXCESSIVE CONTACT WITH HYDRAULIC FLUID AND LUBRICANTS SHOULD BE AVOIDED.
WARNING:
MAINTENANCE PERSONNEL
WARNING:
DISCONNECT TOOL FROM ITS POWER SOURCE BEFORE PERFORMING MAINTENANCE.
WARNING:
BE SURE POWERUNIT IS DISCONNECTED BEFORE CLEANING OR WHEN REPLACING WORN
OR DAMAGED COMPONENTS. SEVERE PERSONAL INJURY MAY OCCUR IF POWER SOURCE
IS NOT DISCONNECTED.
The performance of any tool depends upon good maintenance practices. Following these minimal
requirements for service and care will extend the life of your tool.
*Only use a hydraulic power source equipped with relief valves and pressures set within
specified limits.
*Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.
*Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
*Proper care by operators is necessary in maintaining full productivity and reducing downtime.
*Check tool, all hoses and all couplings daily for damage or air/hydraulic leaks. Tighten or replace (if
necessary).
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 30534 or similar Teflon® infused pipe
dope is recommended.
however, pieces may enter the hydraulic system and cause malfunction and damage. Use 1 1/2 wraps
of tape on each thread. Cut off all loose tape ends. Tighten until fitting feels snug and then go 1/2 to a
full turn past that point.
MUST
READ AND UNDERSTAND ALL WARNINGS AND CAUTIONS.
CAUTION:
Teflon tape is an excellent thread sealer. If it not properly applied,
CAUTION:
Over tightening can easily distort the threads.
5
10/13