Any other servicing should be performed by qualified service personnel.

WALL OR CEILING MOUNTING

THE EG4800DGP BRACKET SHOULD BE MOUNTED TO A STRUCTURE THAT IS CAPABLE OF
SUPPORTING THE BRACKET AND HEATER COMBINED WEIGHT. IDEALLY THE BRACKET SHOULD BE
BOLTED TO A WALL STUD, ROOF TRUSS OR TO A BLOCK WALL USING THE PROPER MOUNTING
HARDWARE. THE HEATER SHOULD BE MOUNTED AS CLOSE TO THE RECEPTACLE AS POSSIBLE TO
ELIMINATE THE USE OF AN EXTENSION CORD.
Drill two holes in a wall/ceiling, the distance of the holes should match the bracket. Screw two M10*30 screws
(not included in samples) to wall/ceiling, male sure the bracket is secured, hung the heater as below photo, let
the hand-driven (provide with sample) go through installation opening. Secure the screw by a nut.
Mount with bottom of heater at least 2.4 m above floor or grade.
CAUTION: MOUNT WITH BOTTOM OF HEATER AT LEAST 2.4 m ABOVE FLOOR OR
GRADE
ATTENTION : INSTALLER À AU MOINS 2,4 m DU PLANCHER.