Aircommand Sparrow Mk4 Manual Manual - Página 10

Procurar online ou descarregar pdf Manual Manual para Ar condicionado Aircommand Sparrow Mk4. Aircommand Sparrow Mk4 17 páginas. Air conditioning unit
Também para Aircommand Sparrow Mk4: Manual do Proprietário (17 páginas)

Aircommand Sparrow Mk4 Manual Manual

Commissioning of the Unit

1. Turn the power on at the circuit breaker.
2. Press the ON/OFF button and press the MODE button to
select FAN.
3. Cycle through the LOW, MED and HIGH fan speeds checking
that all speeds run.
4. Set mode to COOL, adjust temperature via up/down
buttons to 4˚C below the display temp (ie room temp)
compressor will start within three minutes.
5. Set mode to HEAT, similarly set temperature to 4˚C above
the display temperature. Compressor will start within three
minutes. After a few minutes the fan will start and warm
air will be apparent.
NOTE: Regardless of the mode selected there will always be at
least a 3 minute delay before the compressor starts. If the unit
is turned off it is important that the compressor be given at
least 3 minutes before being re-activated

Maintenance

I. PLENUM FILTERS
The plenum fi lters are the only parts that require routine
maintenance. They must be cleaned periodically to ensure that
they do not become clogged with dust and other particles.
Blocked fi lters must be cleaned frequently to maintain cooling
& heating performance
To clean the two plenum fi lters, fi rst remove them both from
the plenum by pulling them out of the assembly.
Fig 17: Plenum fi lter when removed.
The state of the fi lters can be ascertained from its appearance,
if they appear clogged then they should be cleaned. Generally
the fi lters can be cleaned suffi ciently by tapping them
together to shake loose the dust and particles trapped inside.
WARNING
Airborne particles can pose a health risk, particulalry to young
children and the elderly. Ensure that fi lters are cleaned in a
safe and well ventilated area.
If a more thorough clean is required then the fi lters can be
washed out using warm soapy water. Care must be taken to
avoid ripping the fabric.
The fi lters should be cleaned every two weeks or more when in
use. Prolonged use, higher concentrations of airborne particles
and various other factors may result in the fi lters needing to
be cleaned more often.
Replacement fi lters can be ordered directly from Aircommand.
10
II. MOUNTING BOLTS
Aircommand suggests that the hold down bolts are initially
checked for tightness within the fi rst 3 months of installation,
and thereafter every 12 months if the van is in constant use.
III. STORAGE
The air conditioner should be run on a routine basis to ensure
the components remain in working order.
If the van is in storage or is to remain unoccupied for an
extended length of time it is recommended that the air
conditioner is allowed to run uninterrupted for 20-30 minutes
once every six months.
For long term storage outdoors, or to protect your Sparrow
from winter storms and weathering when not in use, a
protective cover can be purchased from Aircommand, please
call for details.
IV. WARRANTY CLAIMS
The unit comes with a one year manufacturer's warranty from
date of purchase. It is IMPORTANT that you read and
understand the conditions of the warranty agreement which
are included with the unit.
If you have a claim please contact Aircommand directly on
(+61) 8 8345 8444, alternatively you can fax (+61) 8243 0628 or
Please have your unit serial number ready.