Full Automatic Mode: In automatic mode, set pressure and operating
pressures are shown on the display. Adjust the pump's pressure by pressing the
"+" or "-" button. Setting ranges from 1.5 to 5.5bar.
Forced Start Mode: In forced mode, motor speed is shown on the display.
Adjust the motor rotations' speed by pressing "+" or "-" button. The speed ranges
from 2,500 to 5,200 rpm.
Hold on the "+" and "-" button simultaneously for 1.5 seconds to reset the pump.
Faulty LED Indicator Guidelines
Set
Pressure
Setting
pressure
switch
1. Power supply failure
2. Pipeline leakage
3. The pump is blocked
Operating
Pressure
-SMART45
Operating
pressure
M
Warning Indicator
_
+
up
down
Lights
Switch on the power supply. Check the
cables and cable connection for defects,
loose connections or for blown fuses in the
electrical installation.
Check whether there is any leakage in the
pipeline or the tap and repair.
Check whether there is foreign matter in the
pump and clean. The pump will work
normally. The indicator light will then turn
off. If not, contact authorized D&S dealer.