ADEMCO Ademco VISTA-20P Manual de início rápido - Página 4

Procurar online ou descarregar pdf Manual de início rápido para Sistema de segurança ADEMCO Ademco VISTA-20P. ADEMCO Ademco VISTA-20P 6 páginas. Programming auto arming and disarming schedules
Também para ADEMCO Ademco VISTA-20P: Manual de instalação rápida (2 páginas), Manual de programação (17 páginas), Manual do utilizador (20 páginas), Manual de programação (17 páginas), Manual de instalação rápida (2 páginas), Manual de instalação rápida (2 páginas), Manual de programação (2 páginas), Manual rápido (2 páginas)

ADEMCO Ademco VISTA-20P Manual de início rápido
 Summary Screen will appear. Press * to continue or # to go back to make
changes.
 At this time we will not enter Alpha Descriptors. We recommend using *82
for this. (Page 9-1 of the Installation and Setup Guide) Press "0"
 You are ready to enter the next zone. Repeat step 9a for each zone.
NOTE: If you have any unused hardwired zones, these zones should be disabled
using Zone Type 00. Then enter 1 when asked to delete zone. We also
recommend adding a resistor to the zone as well.
When all zones are entered, press 00 at the screen where is asks you for a zone
number to exit.
Step 9b: Wireless Device Zone Programming (*56) (Page 5-1 and 5-7 of the
Installation and Setup Guide)
 Enter *56
 Set to Confirm will be displayed on the screen. This means: Are you
installing wireless devices? Press 1 = Yes
We will be using zones 9-48 (Wireless Transmitter Zones) for this step.
 Enter the Zone Number you wish to program and press *. A summary
screen will be displayed. Press * again to advance past the summary
screen.
 - Enter the Zone Type (ZT). (Refer above or go to page 5-2 in the
Installation and Setup Guide for the exact types). Press * to continue.
 Enter the partition number (PT 1 or 2). (NOTE= Partition 3 is for common
areas between partitions 1 and 2). Then press *.
 Report Code (RC) should be left at 01. The summary will show 10 though
this is correct. Press * to continue
 Enter Input Type
o 2=Aux Wired
o 3=RF Supervised
o 4=UR Unsupervised
o 5=Button type RF transmitter
o Then press * to continue
 You will trip the sensor you are entering. Upon activating the sensor, the
keypad will display the S/N of the device. Confirm that the S/N on the
keypad display and device S/N are both the same by entering "*". If not hit
# and reenter.
 Verify the screen is correct and hit * to continue.
 At this time we will not enter Alpha Descriptors. We recommend using *82
for this. (Page 9-1 of the Installation and Setup Guide) Press "0"
 You are ready to enter the next zone. Repeat step 9b for each zone.