DYNACO Dynalogix II Manual elétrico - Página 5
Procurar online ou descarregar pdf Manual elétrico para Painel de controlo DYNACO Dynalogix II. DYNACO Dynalogix II 12 páginas.
Setting Limits
If door moves in the opposite direction of JOG DOWN button, door is out of phase.
STOP
Turn power off and switch T2 & T3 on the terminal block. Turn power on and return
to step one of the set limit section (2.0/Step1).
DYNACO USA, INC,
5. Press and release the Enter button. Display should change to ClsLimit.
6. Press and release the Enter button. Display should change to JogToCls.
See figure 2.0-3.
7. Press the JOG DOWN button to bring the door down to desired close
position. See figure 2.0-3.
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 2.0-3: Jog Down Button
8. Press and Release the ENTER button to save limit setting. Display will
change back to: ClsLimit_Set--OK .
9. Press and release either red arrow buttons to scroll up or down to the
PhtLimit (photo eye shut off position). See figure 2.0-4.
TIMERS
OPEN
JOG
UP/RESET
JOG
MC/PB
DOWN
CLOSE
TIMERS
MENU
Figure 2.0-4: Arrow Buttons (Scroll)
10. Press and release ENTER button. Display will change to:JogToPht_Enter.
11. Use the JOG UP/RESET button to bring door up one inch above the photo
eyes. See figure 2.0-5.
RUN
CLOSE
PROGRAM
AC/LOOP
ENTER
RUN
CLOSE
PROGRAM
AC/LOOP
ENTER
The Leader in Door Safety & Design
4
Press the
JOG DOWN
button to bring
door down.
Display
should read:
MESSAGE DISPLAY / COUNTER
JogToCls
Enter
Press and
release either
arrow buttons
to scroll up or
down to:
MESSAGE DISPLAY / COUNTER
PhtLimit