CAUTION
Do not submerge the meter.
8. When the nutator turns freely, as-
semble and install following the
instructions below.
Assemble Nutator
1. Assemble the nutator disc and nuta-
tor halves. Install the O-ring on the
nutator inlet.
2. Install the nutator in the meter hous-
ing. Make sure the nutator O-ring fits
properly against the meter inlet.
3. Secure the nutator with the metal
clips. Beginning opposite the inlet,
install a clip in each slot in the hous-
ing. Push each clip down firmly until
seated.
4. Place the signal generator on the nu-
tator pin. Make sure it rotates freely
on the pin.
5. Coat the O-ring lightly with bearing
grease and seat securely on the
coverplate.
6. With the display facing up, turn the
coverplate to the desired orientation.
Align holes on coverplate and hous-
ing.
7. Secure the coverplate by evenly
tightening screws to 25 to 35 in. lbs.
Storage
After thoroughly cleaning the meter, dis-
connect the battery and store the meter
in a clean, dry location.
Battery Replacement
Your meter is equipped with a field-
replaceable 9-volt alkaline battery.
If the meter's readout should become dim
or blank, replace the battery.
When the battery is disconnected or
fails, the Batch and Cumulative Totals
return to zero.
Factory and Field Calibrations are not lost
when the battery is replaced or power
is lost. They are saved in the meter's
computer and are available after a new
battery is installed. You do not need to
repeat Field Calibration.
Check the battery and terminals at least
every year to ensure proper operation. It
is strongly recommended that terminals
be cleaned annually.
NOTE: The battery can be replaced
without removing the meter from the
hose or pipe.
To replace battery or clean terminals:
1. Remove the two large and two small
screws from the battery coverplate
located on the lower portion of the
meter face. (Figure 9)
2. Remove the battery coverplate and
gasket. (Figure 10)
Figure 9
Figure 10