ADEMCO 5707 Manual de instruções de instalação - Página 4
Procurar online ou descarregar pdf Manual de instruções de instalação para Alarme de fumo ADEMCO 5707. ADEMCO 5707 12 páginas. Smoke detector with built-in wireless transmitter
Wireless Transmission
Path Test
A good RF transmission
path must be established from the proposed mounting
location before permanently
installing the smoke detector.
To determine
that
there is good signal reception from the proposed location, do the following:
1.
2.
3.
4.
5.
Activate the wireless system's test mode.
Depress and hold the smoke detector's TEST button for at least 45 seconds.
Within 15 seconds, the detector's
horn will start to sound and the unit will
begin to transmit alarm signals about once every 12 seconds.
The wireless system's console will emit at least 3 tones each time an alarm
transmission
is received,
and will display
the transmitting
detector%
ID
number.
When the above has occurred,
release the button.
Within 10 seconds the
detector's horn will stop.
About 1 second later the ID number will clear from
the console display.
If the console does not respond
as noted, move the detector
to another
location and repeat the transmission
path test until a satisfactory location can
be found.
Detector Mountina Procedure
1
2.
3.
If the bracket is ir%talled on-the detector, remove the bracket by depressing
the release tab marked PRESS, then pivot the bracket away and free of the
detector.
Use the bracket as a template to locate and mark two mounting holes. Drill
two 3/1 6 inch diameter holes, and insert the plastic expansion anchors.
Hold
the bracket in place and thread the two screws (supplied) into the anchors.
Be careful
to correctly
orient
the UP arrow on the bracket
for correct
positioning of the detector if mounting on a wall. Tighten the screws.
Install the detector
(with batteries
installed)
onto the bracket
as follows,
referring to Fgure 4
Hook the detector over the loop at one end of the bracket, then swing the
detector gently upward toward the release tab at the other side of the bracket
until the detector snaps into the locked position. Test the detector immediately
after completing the installation.
Important:
Caution should be observed during installation to prevent dust, hair
and other foreign matters from contaminating
the optical sensing mechanism.
/
(
BRACKET
"PRESS,'
LEVER
FDETEcTOR
"PWARDAND
PUSH FIRMLY
UNTIL DETECTOR
LOCKS
INTO
POSITION
ONTO
BRACKET.
DETECTOR
4. TO RELEASE
BRACKET
AFTER
MOUNTING,
PUSH uPWARD
ON
LEVER MARKED
,'PRESS",
LOWER
THAT SIDE OF DETECTOR
ANO
THEN UNHOOK
FROM
BRACKET
AT OTHER
SIDE.
1. MOUNT
RACKET
SECURELY
TO CEILING
WITH SCREWS
SUPPLIED.
2. INSTALL ONE ENO (END
OPPOSITE
IIPRESS',
LEVER)
OVER HOOK ON BRACKET
TO
SUPPORT
THAT SIDE OF THE
DETEcTOR.
Figure 4.
Mounting
the
Smoke Detector
-4–