6: Open the second box and power up that unit (SE-6600 "B"). Repeat steps 3 and 4 above to
access the Front Page and to configure the Cipher Config as before.
Make sure to use the same
passphrase as on SE-6600 A.
7: Click on LAN Config from the menu. Change the IP Address of SE-6600 B to 192.168.1.2
and leave all other parameters at defaults, as shown in Figure 4.
Figure 4 – SE-6600 LAN Config Screen, Showing New IP Address
Click the Save button. A Server Status Message screen will appear and the unit will reboot.
(Allow several seconds for this.)
8: Using items from inside the box of SE-6600 A, install the Direct PC adapter one one end of
the supplied LAN cable and the Remote PC adapter on the other end. This combination creates
an RS-232 crossover (null modem) cable that may be used to connect the serial port of PC A to
the COM1 port of SE-6600 A. Do the same with the cable and adapters from the box of SE-6600
B and use that assembly to connect PC B to the COM1 port of SE-6600 B.
9: Connect a null modem cable between the COM2 ports of SE-6600 A and SE-6600 B. With the
PCs running terminal emulation programs, it should be possible for each PC to send characters to
the terminal of the other across the link, as shown in Figure 5 below. You will not see the
characters being typed on the local screen unless "Local Echo" is enabled.
Figure 5 – Sample Terminal Output for PC A and PC B
3