DCB SE-6600 Manual de início rápido - Página 4
Procurar online ou descarregar pdf Manual de início rápido para Hardware de rede DCB SE-6600. DCB SE-6600 4 páginas. Serial encrypter
In this configuration, the communications between the two PCs are taking place "in the clear",
without encryption enabled. (The "Encrypting" LEDs on the SE-6600 units will be off.) The
next step will turn link encryption on.
10: With the LAN cable still connected to SE-6600 B, open the web browser and enter
http://192.168.1.2
(the new IP address from Step 7). Click on Cipher Config from the menu of
SE-6600 B to display the screen shown in Figure 3, and this time, click on the red rectangle
which reads, "Enable Block Mode Cipher".
This not only activates the encryption on the SE-
6600 B unit, but also sends a message to SE-6600 A to do the
same. An Enabling Block Mode
Cipher screen will appear, with a message to wait while the action takes place. (Note that SE-
6600 A could have been used to send the message to SE-6600 B instead.)
Now the "Encrypting" LEDs on the SE-6600 units will be lit, and the terminal-to-terminal
communications described in Step 9 should once again be possible.
Clicking on Port Activity from the menu displays a screen similar to that shown in Figure 6
below. Whenever either PC sends terminal messages to the other, the Serial counters will
increase, but the Network counters will also increment due to the SE-6600 units communicating
with each other, even in the absence of terminal activity.
Figure 6 – SE-6600 Port Activity Screen, Showing Byte Counters
4