PLACING & ANCHORING - ELECTRICAL
STEP 3: PLACING & ANCHORING
Lift and place the cooktop in the opening. Be careful
not to pinch the power cord or gas inlet between
anything. Anchor the cooktop; ensure that the appli-
ance is in place and level (See Fig.7).
For cabinets with side access, screw the 2 "L" shaped
brackets (supplied) into the holes provided using the
#10 sheet-metal screws as shown in Fig.7 cooktop.
Then using the 1/4 - 20 bolt and nuts (supplied),
anchor as shown.
For cabinets with no side access, first fasten the brack-
ets to the cabinet side wall using a suitable fastener.
Then drill two 5/32" dia. holes upward into the bot-
tom of cooktop and fasten as shown in Fig 7. coun-
tertop.
FIG. 7
Side access anchoring:
Cooktop
777fig09
Bottom access anchoring:
Countertop
5
STEP 4: ELECTRICAL CONNECTIONS
POWER REQUIREMENTS:
120 VAC, 60 Hz.
7 Amp.
(Use 15 Amp. Circuit)
Always disconnect electric supply cord from the wall
outlet or service disconnect before servicing this appli-
ance. Observe all governing codes and ordinances
when grounding, in absence of which, observe
National Electrical Code ANSI / NFPA No. 70-1987.
RECOMMENDED GROUNDING METHOD
This appliance is factory equipped with a power sup-
ply cord with a three-prong grounding plug (with
polarized parallel blades). It must be plugged into
a mating grounding, type receptacle, connected to
a correctly polarized 120 Volt circuit. If the circuit
does not have a grounding type receptacle, it is the
responsibility and obligation of the installer or user to
have the existing receptacle changed to a properly
grounded and polarized receptacle in accordance with
all applicable local codes and ordinances by a quali-
fied electrician. In the absence of local codes and
ordinances the receptacle replacement shall be in
accordance with the National Electrical Code.
THE THIRD PRONG SHOULD NOT, UNDER ANY
CIRCUMSTANCES, BE CUT OR REMOVED (See
Fig. 8). (See Fig. 9).
Receptacle Box
FIG. 8
Cover Plate
Three
Prong
Plug
Three Prong
Receptacle