DDC Sentry VOIP V2 Manual - Página 11

Procurar online ou descarregar pdf Manual para Telefone DDC Sentry VOIP V2. DDC Sentry VOIP V2 20 páginas.

DDC Sentry VOIP V2 Manual

System Settings

Set the DDC_VoIP phone audio levels, relay options, Syslog details and time of day functions in
this section. Audio levels for each phone should be recheck on site.
The on board relay/s may be use for gate access control, back ground lighting / camera. They
can be remotely activated or enable when the DDC_VoIP phone is in use.
The Administration Password is used to gain access to these web pages. For added
security set and document this password. The phone is supplied with this field cleared.
The microphone used by the handset (if fitted) and in the hands-free circuit, is adjusted to suit
site background noise, when possible keep this level low, as un-necessary noise will be
transmitted back to the remote operator.
The Handset and speaker phone levels are also set to suit back ground noise. Whilst in
conversation, this level may be temporary altered by pressing the 'B' and 'C' key on the back of
the unit to increase or decrease the level respectively.
Set the Ringer Volume level to suit site conditions.
The onboard relay may be activated remotely by dialling the digits that matches the fields for
Relay 1 & Relay 2 code. Note that relay 2 is optionally fitted.
The period the relay will stay active is set in the Relay on timer field. Setting this field to 0, will
cause the relay to remain on for the duration of the call.
Either one of the relays may be configured to switch on when the phone is in use. If this is
required then set the Relay Inuse option to On and select one of the available relays. Note, that
when this option is used the Relay on timer period is bypassed.
Conversation period may be limited if desired, to set this, enter a period in minutes into the
Conversation Timer field. If no timer is required then enter a 0 to disable this function.
NOTE: ACA maximum levels for:
handset models be set 5 for microphone and 25 for handset output.
hands-free microphone level to be set to 7.
Dallas Delta Corporation Pty.Ltd.
ACA level = 5 for handset, 7 for hands-free
ACA level = 25
Page 11