Galvin Engineering Safe-Cell 50150 Manual de instalação do produto

Procurar online ou descarregar pdf Manual de instalação do produto para Produto de canalização Galvin Engineering Safe-Cell 50150. Galvin Engineering Safe-Cell 50150 4 páginas. Prison basin set

Galvin Engineering Safe-Cell 50150 Manual de instalação do produto
®
Safe-Cell
Prison Basin Set
PRODUCT CODE:
- 50150
SPECIFICATIONS
 The Safe-Cell
®
Timeflow Push Button Valve is used in prisons, detention centres, high risk institutions,
sporting facilities, schools and public area applications
 Once activated, this timed flow product will allow water to flow for approximately 15 seconds*
Designed for easy bench installation (maximum thickness 10mm)
 Time is based on set at 500kPa, 4LPM @ 22˚C. Time is affected by temperature, flow rate and pressure
 Chrome plate finish
Note: This is a single temperature product, so if warm water is required this needs to be premixed prior to
reaching the valve. This can be done by using a CliniMix
IMPORTANT: All Safe-Cell
premises in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Maximum Working Temperature (°C)
Nominal Flow Rate (LPM)
Construction
Finish
NOTE: Galvin Engineering continually strive to improve their products. Specifications may change without
notice.
TOOLS REQUIRED
Power drill
Spanner or adjustable crescent
®
prison taps are tested in accordance with AS/NZS 3718 and leave our
Version 1, 30 August 2018, 1 of 4
®
Thermostatic Mixing Valve.
½" BSP – Male
Dome Outlet
Time flow cartridge
Min
100
Max
500
Min
5
Max
70
2.55
Brass
Chrome