FIG.G
FIG.H
FIG.I
14-003 w ww.powercommander.com
Wire tap
Grey wire
PCV
9
Locate the stock Throttle Position Sensor. This sensor
is located on the left side of the throttle bodies.
10 Cut a 1" slit in the sheathing for the TPS harness. This
allows access to the wires.
11 Using the supplied wire tap crimp the ORANGE wire
(Fig. G).
12 Connect the GREY wire from the PCV harness to the
wire tap (Fig. G).
13 Attach the ground wire from the PCV harness to the negative terminal of the
battery (Fig. H).
14 Install the PCV to the side of the battery using the supplied velcro (Fig. H)
Make sure to clean both surfaces with the alcohol swab before attaching.
15 Reinstall side panels and seat.
16 Remove the right hand side fairing
17 Locate the O2 sensor connector. It is a BLACK 4 pin connector located on the
right hand side of the bike.
18 Unplug this connector.