TRUNK CABLE INSTALLATION
1.
If desired, remove the rear housing cover by unscrewing the two thumbscrews (Figure 6).
2.
Bring the trunk cable in through the desired side of the ASCEND housing.
3.
Snap the retention clip onto the bridge lance forms, an audible click should be heard when installed correctly. It is recommended when using multiple trunk cables
to begin your installation at the bridge lance forms closest to the trays and progress toward the rear of the housing (Figure 13).
4.
If it is required to release the retention clip, push down on the lever and slide the clip out from the lance forms (Figure 14).
5.
With the retention clip snapped into place, route the fiber in an S-shape manner to make the connections to the cassettes (Figure 15).
6.
Loosely applying Velcro to fiber groups provides further cable management and organization (Figure 16).
7.
To provide ease in cable routing, each row should be fully populated beginning with the bottom most tray before moving upward to the next (Figure 17).
Figure 13
Figure 17
LC UNIBOOT REVERSIBILITY
1.
Flip the connector over so that you are looking at the white body of the connector (Figure 18).
2.
Unlatch the push-pull tab from the body of the connector by pushing the tab in the slot to the left (Figure 19).
3.
Pull the push-pull tab away from the body of the connector (Figure 20).
4.
Once the push-pull tab has been removed from the body, reinsert the tab on the opposite side of the connector body (Figure 21).
Figure 18
4.18.19
Figure 14
Figure 19