AFL ASCEND Instruções de instalação - Página 4

Procurar online ou descarregar pdf Instruções de instalação para Hardware de rede AFL ASCEND. AFL ASCEND 4 páginas. Splice cassette
Também para AFL ASCEND: Instruções de instalação (4 páginas)

MTP
PRO REVERSIBILITY*
®
FEMALE-TO-MALE GENDER CHANGE
1.
Place the connector inside of the port on the MTP Pro Field Tool that is labeled "pin." A click should be heard (Figure 22).
2.
Remove the pin holder from the MTP Pro Field Tool. Ensure that the holder is populated with pins (Figure 23).
3.
Place the pin holder inside of the port labeled "Exchanger" (Figure 24).
4.
Remove the pin holder (Figure 25).
5.
Remove the connector.
Figure 22
MALE-TO-FEMALE GENDER CHANGE
1.
Place the connector inside of the port on the MTP Pro Field Tool that is labeled "pin." A click should be heard (Figure 26).
2.
Remove the empty pin holder from the MTP Pro Field Tool (Figure 27).
3.
Place the pin holder inside of the port labeled "Exchanger" (Figure 28).
4.
Slide the green tool (included with the MTP Pro Field Tool) onto to the pin holder (Figure 29).
5.
Squeeze down on the MTP Pro Field Tool (Figure 30).
6.
Squeeze the handles on the green tool (Figure 31).
7.
Pull the pin holder out of the port (Figure 32).
8.
Release the MTP Pro Field Tool (Figure 33).
9.
Remove the connector from the port.
Figure 26
Figure 30
POLARITY CHANGE
1.
Insert the connector key up into the port on the MTP Pro Field Tool that is labeled "Polarity."
A click will be heard when the connector is properly installed (Figure 34).
2.
Remove the connector from the port.
*These instructions apply to Multimode applications only
4
Figure 23
Figure 27
Figure 31
(800) 235-3423 • (864) 433-0333 • AFLglobal.com
Figure 24
Figure 28
Figure 32
Figure 25
Figure 29
Figure 33
Figure 34