Maintronic DASPip UP Manual rápido - Página 5

Procurar online ou descarregar pdf Manual rápido para Controlador Maintronic DASPip UP. Maintronic DASPip UP 6 páginas. Power pwm actuator 1ch

5.3 Adjust Min-Level
In some situations it is necessary to readjust the min level. If no
DALI is available, the Min level can also be set via a 230V Push-
button connected to the tastDIM *. Perform programming with
the following steps within 15 minutes after power-on:
1
START
4x
min-level
2
PROG
> 1s
> 1s
3
SAVE
1x
> 2s
min-level

7. Protection functions

Short-circuit shutdown
When a short circuit occurs, device automatic switch-off. Every
30 seconds is tested whether the short circuit is still present.
When short circuit is eliminated, device restart automatically.
If the error is still present after 5 minutes, device switch off
completely.
LED
Power limitation at overtemperature
flash
In the event of overtemperature, an automatic derating oc-
curs, which means that the dimmer's power is throttled and
the load is dimming down.
Important!
The connected load is reduced depending on the type of ins-
tallation:
Installation in hollow or wooden walls by 15% as well
10% for each 5 ° C exceeds the ambient temperature of
25 ° C
LED
LED
light up
13
8. Attachment
8.1 Excerpt from the technical data
DASP ip INS /
DASP ip UP
PWM output
Max. output current
Ballast-relay
Switched phase L´
Power supply
Ceiling / installation housing (DASPip INS)
Licensed under DM/053379 of Tridonic
Housing mode
DASPip INS: L=101,5 x B=51 x H=29,5 mm
Dimensions
DASPip UP: L=46,5 x B=70 x H=30 mm
IP Code according to
DIN EN 60529
Protection class
Temperature
(environment) ta
Detailed technical data can be found in the data sheet.
14
1 channel - diming range 0...100 %
125 Hz
3A
switch, not potential-free,
switched phase
1 x 16 A/ 230 V AC
ü
220V-240V AC 50 / 60Hz
flush mounted (DASPip UP)
IP20 10mm/5KV
II
0° – 50° Celsius
15