7106A and 7108A
1.
Check that the proposed location of the
fan will not foul joists, existing wiring or
other internal wall features (wall thickness
between 110 and 310mm). Use template
provided to mark out hole. Cut a hole
through the wall ø230mm. Screw fan
assembly to internal wall via four corner
openings, see Figure A, (appropriate
fasteners to be used for each installation
not provided).
Figure A
2
Fan
Assembly
3
2. Remove termination cover see Figure B,
(screws marked with '1', '2', '3').
Figure B
Screws
labelled 1, 2,
3, retain the
terminal cover
to the chassis.
2 of 4
MaxAir Wall Exhaust Fan Installation Instructions /Warranty Card
1
3. Electrician to make electrical connections
as shown, using three core, 1mm
Replace termination cover.
7106A Connection Diagram
MOTOR
YL
RD
GR
BK
7108A Connection Diagram
MOTOR
RD
GR
YL
BK
4. With fan assembly mounted on the internal
wall, cut PVC sheet to suit wall depth.
2
cable.
Figure C
External
Isolating Switch
A/P
N
E
1
2
External
Isolating Switch
A/P
N
E
1
2