Airflow QT 150T Manual de instruções de instalação e funcionamento - Página 10

Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Ventilador Airflow QT 150T. Airflow QT 150T 17 páginas. Quietair 150mm axial fan. twospeed fan (220/260m3 /hr) with delay start and adjustable timer contro

Airflow QT 150T Manual de instruções de instalação e funcionamento
Installation and Operating Instructions
6.3
DANGER
Fig 4
2. Boreholes
Position the housing, then mark and drill the holes and mount it with at least two
fastening screws and wall plugs.
3. Backdraft shutter and guide vane
- If required backdraft shutter (included in delivery) can be installed behind the guide
vane (Fig 6).
- During the housing installation, the guide vane should be mounted vertically.
- Before final assembly stick on the rubber foam strips (included in delivery) (Fig 6).
Fig 6
Electrical installation/Commissioning
Safety instructions listed in Chapter 1.2 should be observed
-
All electrical installations to be carried out by an approved electrician
in accordance with presented manual and wiring diagrams.
Fan should be fitted with a 3A fuse at all times.
-
-
The relevant standards, safety regulations (for instance DIN VDE 0100)
and technical connection regulations of the energy supply company
should be observed!
-
An all-pole mains switch/isolation switch, with at least a 3 mm contact
opening (VDE 0700 T1 7.12.2 / EN 60335-1) is mandatory by law!
-
Network configuration, voltage and frequency of the power source
should match the information on the rating plate.
10
Fig 5
Fig 7