Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
2. Remove terminal box cover.
A. Terminal box cover with knockout
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved strain relief.
4. Run 3 wires, black, white and green [(or bare) 14 AWG], in
1/2"conduit from service panel to terminal box.
5=
A. V2" conduit
B. UL fisted or CSA approved
Y2"strain relief
C. Black wires
D. White wires
E. Green (or bare) wire connected
with
yeflow-green
wire
Use UL listed wire connectors
and connect black wires
together.
6. Use UL listed wire connectors
and connect white wires
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
7. Connect ground wire to green and yellow ground wire in
terminal box using UL listed wire connectors.
8. Replace terminal box cover.
9. Check all light bulbs to make sure they are secure in their
sockets.
10. Reconnect power.
Vented Installations Only
1. Fit vent system over transition piece.
A. Vent system
B. Transition piece
2. Seal connection with clamps.
Non-vented (recirculating) Installation
Install the deflector inside the lower vent cover with 2 - 3 x 9 mm
screws provided, using the upper screw holes.
A. Deflector
B. Upper
screw
holes
C. Lower
vent cover