Ganz ZC-Y20PH Manual de instruções - Página 12

Procurar online ou descarregar pdf Manual de instruções para Câmara de segurança Ganz ZC-Y20PH. Ganz ZC-Y20PH 20 páginas. Colour cs mount camera

■ Automatic Gain Control (AGC) and Sensitivity Level Settings

● AGC/sensitivity level setting screen 1
An AGC level can be automatically changed, maintained constant or set for OFF. This screen also permits a
sensitivity level to be changed in increments of OFF, 2 times, 4 times, 6 times, 8 times, 10 times, 16 times, 24
times or 32 times.
Move the flashing [→] cursor using the ▲ key and the ▼
key to select the desired AGC mode of "AUTO," "FIX" or
"OFF," then press the SET key to register the setting.
When "AUTO" or "OFF" is selected, the AGC/sensitivity
level setting screen 3 (on the next page) is displayed.
When "FIX" is selected, the AGC/sensitivity level setting
screen 2 is displayed.
Note
When the AGC switch is placed in the OFF position,
the mode is set for OFF.
● AGC/sensitivity level setting screen 2
This screen appears and the [*] cursor in the AGC level
(dB) indication flashes if "FIX" is selected and the setting
is registered. Vary the level by moving the [*] cursor
using the ▲ key and the ▼ key. Pressing the SET key
for registration will advance the display to the
AGC/sensitivity level setting screen 3 "SENS UP."
● AGC/sensitivity level setting screen 3
Move the flashing [→] cursor using the ▲ key and the ▼
key to select the desired incremental parameter and
press the SET key to register the setting. The display will
then return to the initial screen.
Note
When the AGC switch is placed in the OFF position,
the mode is set for OFF.
12
  AGC           →AUTO
                 FIX
                 OFF
  AGC            AUTO
                →FIX
                 OFF
  0    5   10   15  18
  ーーーーー+*ーーー+ーーーー+ーーー
  SENS UP       →OFF
                 X2
                 X4
                 X6
                 X8
                 X10
                 X16
                 X24
                 X32
(dB)