10.

GROUND THE UNIT

WARNING! This unit must always be grounded. Consult an
appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available.
DO NOT CONNECT POWER BEFORE GROUNDING!
Step 1:
Connect the supplied copper wire (CSA 16 mm
GND cable to the GND connector and the
equipment rack or building earth. See Figure 11.
Step 2:
Ground the unit by connecting the "earth wire" of
the power cord to the ground terminal of the AC
supply.
Step 3:
For installations with GX external combiner –
connect the grounding wire supplied with the
external combiner to the earth ground and to the
combiners' grounding lug (see Figure 10).
Corning Optical Communications
)
2
Figure 11. GX Grounding Connection
Quick Installation Sheet | CMA-581-AEN | Page 10