Vent Length
A 31/4 '' x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent
should be used.
The total length of the vent system including straight vent,
elbow(s), transitions and wall or roof caps must not exceed the
equivalent of 140 ft (42.7 m) for either type of vent. See
"Recommended
Standard Fittings" section for equivalent lengths.
For best performance, use no more than three 90 ° elbows.
To calculate the length of the system you need, add the equivalent
lengths of each vent piece used in the system. See the following
examples:
31/4 ' ' x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total
C
A. One 3 _" x !0" (8.3 x 25.4 cm) 90 ° elbow = 25 ft (7. 6 m)
B. 1 wall cap = 40 ft (12.2 rn)
C. 2 ft (O.6 m) + 6 ft (1.8 m) straight = S ft (2.4 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
2 ft
I_
6 ft (1=8 m)
B
ASSISTANCE
Call your authorized dealer or service center. When you call, you
will need the microwave oven model number and serial number.
Both numbers can be found on the model and serial number
plate, which is located behind the microwave oven door on the
front frame of the microwave oven.
If you need additional assistance, call us at our toll free number
listed in the Use and Care Guide, or visit us on the Web.
If any of the installation hardware needs to be replaced, call us at
our toll free number listed in the Use and Care Guide, and
reference the appropriate
part number listed here.
Damper Assembly
Part Number 8206442
Mounting Plate
Part Number 8206319
Upper Cabinet Template
Part Number 8205274
Mounting Screw Kit (includes
parts A-G in "Parts Supplied" in
the "Tools and Parts" section)
Part Number 8206613
Vent Deflector
Part Number 8205980
C
D
A. Two 90 ° elbows = 20 ft (6.1 m)
B. 1 wall cap = 40 ft (12.2 rn)
C. 1 rectangular
to round transition piece = 5 ft (1.5 m)
D. 2 ft (O.6 m) + 6 ft (!.S m) straight = S ft (2.4 m)
If the existing vent is round, a rectangular to round transition piece
must be used. In addition, a rectangular 3" (7.6 cm) extension vent
between the damper assembly and rectangular to round transition
piece must be installed to keep the damper from sticking.
8206590