Gardena 9334-20 Manual de Instruções - Página 6
Procurar online ou descarregar pdf Manual de Instruções para Ventilador Gardena 9334-20. Gardena 9334-20 9 páginas. Electric blower/vac
Cables:
Use only 1.00 mm
size cable up to 40 metres length maximum.
2
Maximum rating:
1.00 mm
size cable
2
ErgoJet 2500 (EJ2500): 2,300 W
Mains cables and extensions are available from your local approved service
centre. Only use extension cables specifically designed for outdoor use.
Connecting the unit [ Fig. O1 / O2 ]:
CAUTION! To avoid damage to the plug, the extension cable must be
inserted into the cable lock.
1. First make a loop with the extension cable
cable lock
e
and pull the extension cable tight.
2. Connect the unit's plug to the extension cable.
3. Connect the extension cable to a 230-V mains socket.
Starting the unit [ Fig. O3 ]:
To start:
v Move the ON/OFF switch
r
to the ON position.
The unit starts.
To stop:
v Move the ON/OFF switch
r
to the OFF position.
The unit stops.
Work positions:
Blow mode [ Fig. O4 ]:
Use your unit as a blower for sweeping debris or grass clippings from
driveways, sidewalks, patios, etc. Also, for blowing grass clippings, straw,
or leaves into piles, or removing debris from corners, around joints, or
between bricks.
Direct air flow by directing the blower tube down or to one side.
Always work away from solid objects such as walks, large stones, vehicles,
and fences.
Clean corners by starting in corners and moving outward. This will help
prevent an accumulation of debris which could fly into your face. Be careful
when working near plants. The force of the air could damage tender plants.
Vacuum mode [ Fig. O5 ]:
Use your unit as a vacuum to pick up dry material such as leaves, grass,
small twigs, and bits of paper.
For best results during vacuum use, operate your unit at high speed.
Move slowly back and forth over the material as you vacuum. Avoid forcing
the unit into a pile of debris as this can clog the unit.
Keep the vacuum tube about an inch above the ground for best results.
WARNING! If the unit becomes clogged, stop the unit and
unplug the extension cord. Wait until the impeller has
completely stopped turning, then remove the vacuum
tubes. Carefully reach into the vacuum opening and clear out the
clogged debris.
This will reduce possible personal injury from the impeller.
4. STORAGE
To put into storage:
Store unit unplugged, well out of the reach of children.
1. Stop unit and disconnect from the mains electricity supply.
2. Allow motor to cool before storing or transporting.
3. Store unit with all guards in place. Position unit so that any sharp object
cannot accidentally cause injury.
Extended storage:
Prepare unit for storage at the end of the season or if it will not be used for
30 days or more.
If your blower is to be stored for a period of time:
1. Stop unit and disconnect from the mains electricity supply.
2. Clean the entire unit before lengthy storage.
3. Open inlet cover and clean any dirt, grass, or debris that has collected.
Inspect the blower and all tubes. Close and make sure the cover is
latched.
4. Use a soft brush to clean air vents and air inlet of debris. Do not use
water.
w
, thread the loop into the
5. Store your unit and extension cord in a well ventilated area and covered,
if possible, to prevent dust and dirt accumulation. Do not cover with
plastic. Plastic cannot breathe and may cause condensation and even-
tual rust or corrosion.
6. Check entire unit for loose screws. Replace any damaged, worn, or
broken parts.
7. Remove tube(s) for easier storage.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
5. MAINTENANCE
WARNING! Stop the unit and disconnect the plug from the
power source before making any adjustments, changing
accessories, or performing maintenance.
Such preventive safety measures reduce the risk of starting the power
tool accidentally.
BEFORE EACH USE
Check for loose fasteners and parts:
Keep all nuts, bolts and screws tight to be sure the product is in a safe
working condition. Be sure all parts are assembled properly.
• Inlet Cover
• Blower Tube
• Vacuum Tubes
• Collection Bag
Check for damaged or worn parts:
Contact your authorized service dealer for replacement of damaged or
worn parts.
• ON / OFF Switch – Ensure switch functions properly by moving the
switch to the OFF position. Make sure motor stops; then restart motor
and continue.
• Inlet Cover – Discontinue use of unit if inlet cover fails to latch properly
or if it is damaged in any way.
AFTER EACH USE
Inspect and clean unit and labels:
DANGER!
Electric shock!
Never clean the ventilation slit with a metal object.
• After each use, inspect complete unit for loose or damaged parts.
Clean the unit using a damp cloth.
• Wipe off unit with a clean dry cloth.
Clean collection bag:
IMPORTANT!
THE COLLECTION BAG MUST BE PROPERLY EMPTIED.
• You must properly empty and maintain the collection bag to avoid
deterioration and obstruction of air flow.
• Remove the collection bag from the unit and empty after each use.
Do not store bag without emptying the bag of all contents (grass, leaves,
etc.).
• Wash the bag once a year. Remove the bag from the blower and turn
the bag inside out. Wash the bag with a water hose. Allow the bag to
hang and dry completely before you reuse the bag.
WARNING! If the unit becomes clogged, stop the unit and
unplug the extension cord. Wait until the impeller has
completely stopped turning, then remove the vacuum
tubes. Carefully reach into the vacuum opening and clear out the
clogged debris.
This will reduce possible personal injury from the impeller.
19