Garmin Fusion Apollo MS-ERX400 Manual do Proprietário - Página 13

Procurar online ou descarregar pdf Manual do Proprietário para Equipamento marítimo Garmin Fusion Apollo MS-ERX400. Garmin Fusion Apollo MS-ERX400 20 páginas.
Também para Garmin Fusion Apollo MS-ERX400: Manual de instruções de instalação (8 páginas)

Garmin Fusion Apollo MS-ERX400 Manual do Proprietário

Update Options

Select
, select the name of the device, and select SETTINGS > UPDATE.
ERX REMOTE: Updates the remote control from a stereo connected to the ETHERNET port or the Fusion
PartyBus network using a valid software update file on a USB flash drive connected to the stereo
Updates, page
10).
FACTORY RESET: Restores all settings to the factory default values.

Network Settings

Select
> SETTINGS, select the name of the remote control, then select NETWORK.
DHCP CLIENT: Sets the device as a DHCP client. This is the default setting for all devices that are not
configured to be a DHCP server.
STATIC IP: Allows you to set a static IP address for the device
GARMIN MARINE NETWORK: Allows the device to be used on a Garmin
and controlled by connected Garmin chartplotters.
RESET: Resets the network configuration on the remote control to factory defaults.
DETAILS: Shows information about the network configuration.
SAVE: Allows you to save changes to the network settings.

Setting the Device as a DHCP Client

This device is set as a DHCP client by default. When set as a DHCP client, the device is configured for use on a
network with a DHCP server. If no DHCP server is present on the network, the device assigns its own local IP
address after a short delay.
NOTE: Although the Fusion PartyBus devices can communicate with each other without a DHCP server on the
network, the devices take longer to connect to each other when you first turn them on. It is highly recommended
to have one properly-configured DHCP server on the network for the best results.
1 Select
> SETTINGS.
2 Select the name of this device.
3 Select NETWORK > DHCP CLIENT > SAVE.

Setting a Static IP Address

If the stereo is configured as a static IP, it is automatically assigned the IP address of 192.168.0.1. You can
change this IP address.
If the stereo is a DHCP client on the network and you do not want the DHCP server to automatically assign an
IP address to the stereo, you can set a static IP address.
NOTE: Every device on the network must have a unique IP address. If you select a static IP address that is the
same as the IP address on the network, the devices will not work properly.
1 Select
> SETTINGS.
2 Select the name of the remote control.
3 Select NETWORK > STATIC IP.
4 Select an option:
• To set the IP address, select IP, and enter the IP address.
• To set the subnet mask, select MASK, and enter the subnet mask.
NOTE: The subnet mask must match all other devices on the network to work properly. A typical subnet
mask is 255.255.255.0.
• To set the default gateway IP address, select GATEWAY, and enter the gateway IP address.
NOTE: The default gateway is typically set as the IP address of the DHCP server on the network.
5 Select SAVE.
General Settings
(Setting a Static IP Address, page
®
Marine Network so it can be viewed
(Software
9).
9