Programming:

Before you start programming

Use the prepared form, which is also a clear table of basic functions, and fill in all the
values you want to change.
If the L8 is not brand new, make sure that you have the correct servicing password,
and if you are not completely sure how the L8 is programmed, always use full
initialisation (Attention: The servicing password is also initialised!).
The L8 can be programmed in 3 ways: remotely by telephone (using the telephone
number), using the machine room audio unit, and or using the service tool program
(connection via USB or using an IP address).
Entry to programming mode
You can enter the programming mode during an incoming connection (calling the L8's
number) or using the machine room audio unit (by pressing
seconds).
Using the voice menu you get through to programming (For administration press 9 ->
For entry to the programming menu press 1).
You are called upon to enter the servicing password in the format servicing password
(don't forget to enter the asterisk after the password).
If the entered password is correct, L8 announces:
"You have entered the programming menu, select the parameter"
The factory setting of the password is 12345, and we recommend that you enter a
different password so that your equipment is protected from other people.
Actual programming
As soon as you have entered the programming mode, you can change any programmable
value or several values, and you can do so in any order. The procedure is simple – first
the number of the function is entered, then its value. An asterisk serves as a separator or
"enter". So in general terms the function has the following format:
The number of the function has three digits (see table). After entering this number and
the asterisk, L8 announces the number of this parameter, its current value and possible
range. After entering the value and the second asterisk, L8 announces "The new value
has been saved" or "Invalid value, the new value has not been saved" if the value falls
outside the permitted range.
For control purposes L8 reads out the number of the parameter and the newly configured
value.
number of function
for longer than 2
value
5