Aqua Logic DSHP Series Manual de instruções de instalação e funcionamento - Página 4
Procurar online ou descarregar pdf Manual de instruções de instalação e funcionamento para Bomba de calor Aqua Logic DSHP Series. Aqua Logic DSHP Series 11 páginas.
Installation Instructions:
1. Place the heat pump on a level concrete or metal pad with at least two (2) feet of space around
the unit to allow room for access to the unit for air flow and maintenance. If the heat pump is to
be mounted outdoors, it must be placed in to a weather proof housing to protect from direct
weather and rain.
2. Connect the plumbing from the tank to the heat exchanger FPT PVC water fittings on the front
of the heat pump. Be careful not to over tighten the plastic fittings.
3. Install flow switch (if supplied) either on the water inlet or outlet side with at least 12 inches of
straight pipe on the inlet side and 6 inches on the outlet side.
4. Submerse into tank the ½" titanium temperature sensor probe in
the water.
Optional titanium dry sensor well: Install in the water inlet
plumbing of the heat pump.
5. Check for water leaks.
6. Plug-in the temperature controller to the flow switch (optional) and then to the heat pump.
If hard wired, the installation must proceed in accordance with national building and
electrical codes by qualified technicians only.
Copyright© 2016 Aqua Logic, Inc. Effective date of 1/2016