Temperature Controller Set-up
This digital controller has been pre-programmed with all the
necessary parameters to ensure reliable service and operation. The
controller is pre-set from the factory with a temperature range from
30 °F to 100 °F with a display resolution of 1 degree °F and with a
1 °F temperature differential.
Temperature Controller Setpoint Set-up
To modify the set point* temperature.
Press and release the "SET" button. SP
will be displayed. Press the "SET" button
again and the pre-programmed set point
temperature will be displayed. Press the
up arrow ▲ to increase or the down
arrow ▼ to decrease the set point.
Once the desired set point value has
been selected, do not touch any of the
keys for 1 minute or press the "SET" and
the "DOWN" ▼ arrow at the same time.
The control will then revert to displaying
the current water temperature, but will
now control the water temperature to the
desired set point.
This indicates that the chiller or heater should be energized.
Temperature Differential:
When the water has reached the set point temperature, the chiller or
heater will switch off and will not switch back on until the water
temperature has changed by 1 °F. This value is known as the
temperature differential between on and off cycles. Refer to the
temperature control parameters table to change the settings.
1
Limited Warranty
This controller has a one (1) year limited warranty.
Aqua Logic, Inc. warrants this temperature controller to be free of
defects in materials or workmanship for a period of one (1) year from
the date of purchase. In the event of a defect or failure of this product,
RETURN THE CONTROLLER WITH PROPER PACKAGING along
with pre-authorized issued RMA number, proof of purchase and / or a
copy of the original bill of sale to the address below, freight prepaid.
COD shipments will be refused. After inspection, to ascertain that
there is a defect due to material or workmanship and that the product
is still under warranty, Aqua Logic will repair or replace the product at
our discretion and return ship the unit, Our liability is limited to the
cost of defective materials. In no case will Aqua Logic assume liability
for consequential damage resulting from any failure. Not covered by
this warranty are damage due to corrosion, abuse, accidental,
alterations, unreasonable or improper use. Aqua Logic is not liable for
payment or field repair work without prior written authorization.
Call or email Aqua Logic for a RMA number.
PH: 858.292.4773
email to: [email protected]
Return the controller to this address below with a copy of the RMA
inside the box within 30 days to:
Aqua Logic, Inc.
Attn: Return Dept. RMA# (put your number here)
9558 Camino Ruiz.
San Diego, CA. 92126
6