Aqua Medic 4014694712114 Manual de operação - Página 4

Procurar online ou descarregar pdf Manual de operação para Controlador Aqua Medic 4014694712114. Aqua Medic 4014694712114 15 páginas.

Aqua Medic 4014694712114 Manual de operação
The pressure regulator regular has been especially designed for use with either salt or fresh water aquaria. To
ensure maximum service life, dependable performance and trouble-free operation, read and follow all
instructions.
1. Technical data
Type:
Code-No.:
Flow rate:
Max. pressure:
Gas:
Material:
Working pressure:
Pressure gauges:
Adjustment of CO
flow:
2
Fig. 1:
1. Working pressure gauge
2. Storage pressure gauge
3. Needle valve
4. CO
hose fitting
2
5. Nut for hose
6. O-ring, washer
7. Mounting nut (for bottle)
8. O-Ring
Available spare parts: Please refer to www.aqua-medic.de.
2. In general
The pressure in CO
bottles is much too high to be handled safely without a proper pressure regulation. Solenoid
2
valves, used for aquaria, are safe for a pressure up to a maximum of 10 bars. Standard tubing may be used up
to 1 bar, special CO
tubes up to 6 bars. The pressure in a CO
2
between 60 and 70 bar. In order to reduce this pressure down to the optimum working pressure of the Aqua
Medic CO
system, a pressure regulator is needed. The CO
2
purpose. It is a rugged instrument, engineered to withstand regular use while providing sufficient delicate
regulation. The pressure regulator regular is a complete top class instrument. The whole unit is chrome-plated
to improve the corrosion-resistance.
The unit is fitted with 2 chrome-plated pressure gauges. The primary pressure gauge shows the CO
inside of the bottle. This pressure is 60 - 70 bar as long as there is liquid CO
pressure gauge shows the firmly adjusted working pressure of 1.5 bar (between 1 and 2 bar).
4
Operation Manual ENG
regular
71011
70 – 1,200 ml/min.
120 bar
CO
only, working pressure 70 bar
2
brass, chrome-plated
1.5 bar (at 70 bar primary pressure), firmly adjusted
2 pieces, plastic-coated for working pressure and storage pressure
needle valve
3
4
1
7
6
5
bottle varies, depending on the room temperature,
2
pressure regulator regular is best suited for this
2
left in the bottle. The second
2
8
2
pressure
2