The pressure regulator regular has been especially designed for use with either salt or fresh water aquaria. To
ensure maximum service life, dependable performance and trouble-free operation, read and follow all
instructions.
1. Technical data
Type:
Code-No.:
Flow rate:
Max. pressure:
Gas:
Material:
Working pressure:
Pressure gauges:
Adjustment of CO
flow:
2
Fig. 1:
1. Working pressure gauge
2. Storage pressure gauge
3. Needle valve
4. CO
hose fitting
2
5. Nut for hose
6. O-ring, washer
7. Mounting nut (for bottle)
8. O-Ring
Available spare parts: Please refer to www.aqua-medic.de.
2. In general
The pressure in CO
bottles is much too high to be handled safely without a proper pressure regulation. Solenoid
2
valves, used for aquaria, are safe for a pressure up to a maximum of 10 bars. Standard tubing may be used up
to 1 bar, special CO
tubes up to 6 bars. The pressure in a CO
2
between 60 and 70 bar. In order to reduce this pressure down to the optimum working pressure of the Aqua
Medic CO
system, a pressure regulator is needed. The CO
2
purpose. It is a rugged instrument, engineered to withstand regular use while providing sufficient delicate
regulation. The pressure regulator regular is a complete top class instrument. The whole unit is chrome-plated
to improve the corrosion-resistance.
The unit is fitted with 2 chrome-plated pressure gauges. The primary pressure gauge shows the CO
inside of the bottle. This pressure is 60 - 70 bar as long as there is liquid CO
pressure gauge shows the firmly adjusted working pressure of 1.5 bar (between 1 and 2 bar).
4
Operation Manual ENG
regular
71011
70 – 1,200 ml/min.
120 bar
CO
only, working pressure 70 bar
2
brass, chrome-plated
1.5 bar (at 70 bar primary pressure), firmly adjusted
2 pieces, plastic-coated for working pressure and storage pressure
needle valve
3
4
1
7
6
5
bottle varies, depending on the room temperature,
2
pressure regulator regular is best suited for this
2
left in the bottle. The second
2
8
2
pressure
2