Avtron AV115 Manual de instruções

Procurar online ou descarregar pdf Manual de instruções para Conversor de multimédia Avtron AV115. Avtron AV115 10 páginas.

8 9 0 1 E . P L E A S A N T VA L L E Y R O A D
I N D E P E N D E N C E , O H I O 4 4 1 3 1 - 5 5 0 8
T E L E P H O N E : ( 1 ) 2 1 6 - 6 4 2 - 1 2 3 0 • FA X : ( 1 ) 2 1 6 - 6 4 2 - 6 0 3 7
E - M A I L : t a c h s @ a v t r o n . c o m • W E B : w w w. a v t r o n e n c o d e r s . c o m
DESCRIPTION
The Avtron AV115 is a modular, two piece incremental encoder
(also known as a tachometer or rotary pulse generator). It provides
a two phase, A Quad B frequency (pulse) output, with comple-
ments. The AV115 mounts on a 115mm C-Face, also known as
a B-Flange.
Because the AV115 is modular, there are no bearings or
couplings required. This, combined with the latest magneto-
resistive (MR) sensor technology, allows the AV115 to
provide superior mechanical performance and increased reliability.
An Avtron AV115 can be configured with one or two independent
outputs. Each output has six signals: (A, B) 90° out of phase, with
complements (A
, B
). A marker pulse with complement (Z, Z
also provided.
Output resolution on the AV115 is determined by the sensor only.
Unlike older models, any PPRs can be mixed and matched.
Selection of the rotor is based only on the shaft mounting require-
ments (and not PPR).
Special option 002 selects an alternate PPR code
defini tion. Example: A-128 PPR with option code
000. A*-1270 PPR with option code 002.
INSTALLATIONs
Refer to the back page of these instructions for outline and
mounting dimensions. Axial float or endplay must be less than
±1.27mm.
In preparation for installing the Model AV115 pulse generator, it is
first necessary to clean both the accessory motor shaft and the
mounting face. These surfaces must be inspected and any paint,
burrs, or other surface imperfections removed.
AV115 PART NUMBERS AND AVAILABLE OPTIONS
Model Housing Type
(Thru Shaft Rotor)
AV115
1- Single Output
C0- Non. Std. Shaft Size
XX- None
2- Dual Output
Thru Shaft Rotor (Metric)
D2- 10mm
DA- 11mm
D3- 12mm
DB- 14mm
DC- 15mm
DD- 16mm
*
Cam Screw Rotor only
D4- 18mm
10mm-60mm
DE- 19mm
DF- 24mm
^ To specify this PPR,
DG- 28mm
also specify modifica
DH- 30mm
tion code 002
DT- 32mm
DJ- 36mm
INDUSTRIAL AUTOMATION, INC.
NOTE
Shaft Size
Cover Style Line Driver
E- Extended
Shaft Cover
F- Flat Cover
DK- 38mm
T- Flat Thru-
DL- 42mm
Hole Cover with
DM- 45mm
Shaft Seal (Seal
DN- 48mm
DP- 52mm
not available
DR- 55mm
on shafts larger
DS- 60mm
than 75mm)
MU- 65mm*
MV- 70mm*
MW- 75mm*
MY- 80mm*
MZ- 85mm*
Equipment Needed for Installation
Provided
AV115 Stator/Housing
Socket Hd Cap Screw
M10 x 20mm (4)
AV115 Rotor
Socket Set Screw
M4 x 6mm (2) or Pre-
installed cam screw
Thread locker (blue)
Installation procedures should be performed only by qualified
) is
personnel. Safety precautions must be taken to ensure machin-
ery cannot rotate and all sources of power are removed during
installation.
ROTOR INSTALLATION
The motor shaft must project at least 16mm from the motor
face. For set screw rotors only: Apply anti-seize compound to
the motor shaft. For all rotors: Slide the rotor onto the shaft with
the marking "This side out" facing out (away from the motor
face). The rotor centerline must match the sensor centerline. To
accomplish this, use the rotor locating gauge (A28503) and slide
the rotor onto the shaft until it is in the proper position as shown
in Figure 1. If a guage is not available, use the stator housing
alignment grooves as show in Figure 3.
STANDARD CAM SCREW ROTOR INSTALLATION
Turn the cam screws of the rotor in the directions shown on the
rotor to engage the cams. Tighten to 5.6 - 6.8 N-m (See Figure2)
using the 3mm hex wrench. Total cam screw rotation will be less
than one turn.
Single/Left
Right Output
Output (PPR)
6- 5-24V in/out
C^- 50
0- Non.
R- 512
F- 60
Std.
S- 600
8- 5-24 V in,
G- 100
C^- 50
V- 900
5-15 V out
H- 120
F- 60
J- 960
high power
A- 128
G- 100
Y- 1024
9- 5-24V in,
B^- 150
H- 120
Z- 1200
5V out
L- 240
A- 128
A^- 1270
N- 256
B^- 150
3- 2000
P- 300
L- 240
4- 2048
N- 256
5- 2500
E- 360
P- 300
D- 4096
B- 480
E- 360
8- 4800
R- 512
S- 600
B- 480
9- 5000
V- 900
Q- 500
Encoder
Instructions
MODEL
AV115
115mm FLANGE MOUNT
MODULAR
Optional
Extended Shaft
Phillips Screwdriver
Cover w/ Screws
2mm Hex Wrench
6-32 x 0.31" (4)
Lock Washers
Shaft Rotors >70mm)
Thru Shaft Cover
3mm Hex Wrench
w/ V-Ring Seal and
8mm Hex Wrench
Silicone Lubricant
Connector
(PPR)
P- 10 Pin EPIC Industrial
J- 960
Y- 1024
w/ Plug
Z- 1200
G- 10 Pin Industrial w/ Plug
A^- 1270
(Northstar pinout)
3- 2000
W- 3 Ft. Cable, Sealed
4- 2048
5- 2500
Z- 3 Ft. Cable w/ EPIC
D- 4096
Industrial
8- 4800
9- 5000
0- Non-
Std.
X- None
Not Provided
(T-Handle Style for Thru-
Modifications
000- No Modification
^
002
-select alternate PPR
assign ment code
004- Add Housing Drain
(single output only)
9xx- Special Cable Length,