Dell SC180 Manual do Proprietário - Página 37

Procurar online ou descarregar pdf Manual do Proprietário para Armazenamento Dell SC180. Dell SC180 37 páginas. Storage center
Também para Dell SC180: Manual do Proprietário (39 páginas)

Dell SC180 Manual do Proprietário
Environmental
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
SC180 Technical Specifications
20% to 80% (noncondensing) with a maximum humidity gradation of 10% per
hour
5% to 100% (noncondensing)
0.21 G at 5–500 Hz for 15 min
1.04 G at 2–200 Hz for 15 min
Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% in
operational orientations only
Z-axis: 30 g 10 ms half sine
X- and Y-axes: 20 g 10 ms half sine
–30.5 to 3000 m (–100 to 10,000 ft)
NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m
to 3000 m (7000 ft to 10,000 ft).
–300 m to 12,192 m (–1000 ft to 40,000 ft)
G2 or lower as defined by ISA-S71.04-1985
37