EarthQuake Cinenova Grande Manual do utilizador - Página 10

Procurar online ou descarregar pdf Manual do utilizador para Amplificador EarthQuake Cinenova Grande. EarthQuake Cinenova Grande 16 páginas. 5/7 channel power amplifier

EarthQuake Cinenova Grande Manual do utilizador
Panel Overview
Rear Panel
1. Replaceable Fuses:
Each mono block is equipped with two (10 Amperes) fuses
designed to protect and monitor the voltage of operating rails
(+/-). If a fuse burns out you may replace it with the following fuse
size: 10A - 250V, 5mm x 20mm, mini fuse slow blow. If fuses
continue to blow check for shorts in the wiring system.
2. RCA Input:
Accepts low-level signal from any source. It takes 1.6V to output
the rated power.
3. Input Selector:
To maintain signal integrity Cinénova-7 provides you with an
"Input Selector Switch". This gives you (installer) the option to
select between RCA or XLR inputs.
4. Fully Balanced XLR Inputs:
We recommend the use of fully balanced XLR inputs in cases
when the distance between the Cinénova and the audio source is
excessive and susceptible to noise interference.
5. Three-way Crossover Switch:
A 3-way switch controls the operation of the output filter. The amp
can run in full-range, low-pass, or high-pass mode to be used for
different applications.
6. Variable Crossover 20Hz-5kHz:
Each monaural block features a built-in variable filter to select the
desired frequency range, with a slope of 12dB/Octave. The fully
buffered filter has a range of 20Hz when set to minimum to
5 kHz when set to maximum. This V/R is inactive when crossover
switch is in by-pass mode.
7. Fused Fault Indicators:
Each fuse carries its own fault LED indicator that illuminates
when the fuse is burnt.
8
. Gold Plated Speaker
Output Binding Posts:
We recommend that you use a high quality wire constructed of
fine, multi-strand copper 10-gauge and up. Wire with a gauge of
16 may be used for short runs of less than twenty feet. We do not
recommend that you use any wires with a gauge equivalent of 18
or higher due to the power loss and performance degradation.
10
1
2
3
FUSE
FUSE
FUSE
10A
10A
10A
RCA
RCA
RCA
INPUT
INPUT
INPUT
CONTROL
CONTROL
CONTROL
XLR
XLR
XLR
HIGH PASS
HIGH PASS
HIGH PASS
BYPASS
BY PASS
BYPASS
LOW PASS
LOW PASS
LOW PASS
5kHz
5kHz
5kHz
20Hz
20Hz
20Hz
FFI
FFI
FFI
SPEAKER
SPEAKER
SPEAKER
OUTPUT
OUTPUT
OUTPUT
9
.
Main Circuit Breaker
The enormous amount of power generated by the amplifiers requires a
stable 120 or 240V connection.
20A circuit breaker. If power to your amplifier is interrupted, check the
circuit breaker on the rear of the unit. If the breaker is in the off position you
may reset it to the on position to restore AC power. If the circuit breaker
automatically trips to the off position.
To ensure proper operation,
we recommend a dedicated 20amp circuit
breaker
because a proper power supply translates to better performance.
Most homes are wired with 20A circuits, but there is a chance that the wall
receptors are rated at 15A. IF IN DOUBT, CONSULT WITH AN
ELECTRICIAN.
10. AC Input Connector
A special heavy duty - 20 Amperes - AC cord is included with every unit. Do not attempt to
replace the AC cord with lesser quality AC cords.
11. 12VDC Trigger
In order for the Cinénova Turn-ON to be controlled via another source connect the 12VDC
trigger input to the 12VDC source output (polarity is not an issue)>20ma. Then set the
manual power switch to OFF and the circuit breaker to ON. Now any time the Cinénova
detects an incoming 12VDC signal it will automatically power on.
4
5
FUSE
FUSE
FUSE
10A
10A
10A
RCA
RCA
RCA
INPUT
INPUT
INPUT
CONTROL
CONTROL
CONTROL
XLR
XLR
XLR
HIGH PASS
HIGH PASS
HIGH PASS
BYPASS
BYPASS
BYPASS
LOW PASS
LOW PASS
LOW PASS
5kHz
5kHz
5kHz
20Hz
20Hz
20Hz
FFI
FFI
FFI
SPEAKER
SPEAKER
SPEAKER
OUTPUT
OUTPUT
OUTPUT
6
7
Your amplifier is supplied with a heavy-duty
Earthquake Sound
11
FUSE
10A
12V DC
REMOTE TURN ON
RCA
INPUT
CONTROL
XLR
CIRCUIT BREAKER
20AMP
HIGH PASS
BYPASS
LOW PASS
5kHz
20Hz
AC IN
FFI
SPEAKER
OUTPUT
8
9
10