Miele DA5341D Instruções de utilização e de instalação - Página 6
Procurar online ou descarregar pdf Instruções de utilização e de instalação para Campânula de ventilação Miele DA5341D. Miele DA5341D 32 páginas. Decorator island hood
Também para Miele DA5341D: Dimensões do produto (2 páginas)
IMPORTANT SAFETY INSTRUCTIONS
Installation
~
, WARNING
To reduce the risk of fire only use
metal ductwork.
~
Any fittings, sealant, or materials
used to install the ductwork must be
made of approved non-flammable
materials.
~
Provided a larger distance is not
given by the manufacturer of the
cooktop, follow the minimum safety
distances between a cooktop and the
bottom of the hood:
– 22" (550 mm) above electric
cooktops,
– 30" (762 mm) above gas cooktops,
– 26" (650 mm) above an open electric
grill or an open electric boiler/fryer.
If local building codes require a greater
safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
~
Do not install this hood over
cooktops burning solid fuel.
~
Do not use an extension cord to
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance,
(e.g. danger of overheating).
6
~
Never connect an exhaust hood to
an active chimney, dryer vent, vent flue,
or room ventilating ductwork. Seek
professional advice before connecting
an exhaust hood vent to an existing,
inactive chimney or vent flue.
WARNING - TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
~
Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable codes and standards,
including fire-rated construction.
~
Sufficient air is needed for
combustion and exhausting of gases
through the flue (chimney of fuel
burning equipment to prevent back
drafting. Follow the heating equipment
manufacturer's guideline and safety
standards such as those published by
the National Fire Protection Association
(NFPA) and the American Society for
Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and
the local code authorities.
~
When cutting or drilling into wall or
ceiling, do not damage electrical wiring
and other hidden utilities.
~
Ducted fans must always be vented
to the outdoors.