Burkert 1066 Manual de início rápido - Página 6

Procurar online ou descarregar pdf Manual de início rápido para Controlador Burkert 1066. Burkert 1066 6 páginas. Control head

ELECTRICAL CONNECTION
Control heads with communication
Bus drive via AS interface standard
No. of valves
max. 3 x 1 W
Bus connection
- ASI shaped cable
- 4-pole plug with round cable
- 4-pole plug at control head
I/O-Code
7 hex (4 outputs, 4 inputs)
ID-Code
F hex (for bit configuration see table)
extended ID codes 1 and 2 = F hex
Profile:
7.F
Data bit
D3
D2
Output
yellow LED
valve 3
proximity
Input
nc
switch 3
P3
P2
Parameter
bit
not connected
Value 0 = Off; value 1 = On
LED
LED
green
red
LED
yellow
LED green
LED red Bus status
off
off
POWER OFF
off
on
No data traffic (watchdog expired
with slave address non-zero)
on
off
ok
flashes
flashes
Periphery error (overload in
sensor supply)
flashes
on
Slave address = 0
off
flashes
RESET
ELECTRICAL CONNECTION
GB
Control heads with communication
Bus drive via AS interface standard
Bus line ASI Unshielded two-wire conductor over which both
information (data) and energy (voltage supply for actuators and
sensors) are transmitted.
Bus connection - Connector for distribution to ASI shaped
cable
- Loose the 2 screws of connector
- Take off the upper part
- Insert the shaped cable with tight fit
D1
D0
- Put on the upper part again
valve 2
valve 1
- Tight the screws - ready!
proximity
proximity
4-pole M12 plug on control head
switch 2
switch 1
P1
P0
ASI-Version A/B-Slave see Operating Instructions type 1066
Bus drive via DeviceNet
Bus line DeviceNet 4-wire cable plus shield which must meet
the DeviceNet specification; with the cable both information
(data) and energy (voltage supply for actuators and sensors) are
transmitted. Before commissioning, read in the EDS file supplied
on diskette or from the Internet.
Bus drive via DeviceNet
CAN_H
white
Data
CAN_L
lines
blue
Drain (shield) n.c.
Pins 2+3: voltage supply 11 to 25 V DC
max. power conumptin 5 W when all valves are actuated
Configuration of the control head with 8 DIP switches
- DIP switches 1 to 6
- DIP switches 7and 8
GB
1 brown, ASI+
2 n.c.
3 blue, ASI-
4 n.c.
V -
black
Pins 2+3
V +
red
DeviceNet address
network data rate
ELECTRICAL CONNECTION
Control heads with communication
Bus drive via DeviceNet
(MAC ID = Medium Access Control Identifier)
DIP1 = off = 0 / DIP1 = on = 1
0
1
MAC ID = DIP1*2
+ DIP2*2
+...+ DIP6*2
DIP 1
DIP 2
DIP 3
DIP 4
DIP 5
0
1
2
3
4
[2
=1]
[2
=2]
[2
=4]
[2
=8]
[2
off
off
off
off
off
on
off
off
off
off
off
on
off
off
off
...
...
...
...
off
on
on
on
on
on
on
on
on
on
DIP 7 DIP 8
Network data rate
off
off
125 kBaud
on
off
250 kBaud
off
on
500 kBaud
on
on
not allowed
For process data and max. length when using drop
lines, see Instr. type 1066.
to DeviceNet specification (see Instr. type 1066)
LED Power single-colour (green):
LED on = voltage present
LED MNS
two-colour (red-green): status indication
GB
5
DIP 6
MAC
5
=16]
[2
=32]
ID
off
0
off
1
off
2
...
...
...
on
62
on
63
Line length
max. 500 m
max. 250 m
max. 100 m