Burkert 1066 Manual de início rápido - Página 4

Procurar online ou descarregar pdf Manual de início rápido para Controlador Burkert 1066. Burkert 1066 6 páginas. Control head

NIEDERLASSUNGEN / BRANCH OFFICE
Chr.-Bürkert-Straße 13-17
Berlin
Ph: (0 30) 67 97 17 - 0
74653 Ingelfingen
Dortmund Ph: (0 23 73) 96 81 - 0
Ph: (0 79 40) 10-111
Frankfurt
Ph: (0 61 03) 94 14 - 0
Fax (0 79 40) 10-448
Hannover
Ph: (05 11) 9 02 76 - 0
www.buerkert.com
München
Ph: (0 89) 82 92 28 - 0
Stuttgart
Ph: (07 11) 4 51 10 - 0
BÜRKERT INTERNATIONAL
A
Ph.
(01) 894 13 33
Fax (01) 894 13 00
AUS
Ph.
(02) 1300 888 868
Fax (02) 1300 888 076
B
Ph.
(03) 325 89 00
Fax (03) 325 61 61
BRA
Ph.
(011) 51 82 00 11
Fax (011) 51 82 88 99
CDN
Ph.
(905) 847 55 66
Fax (905) 847 90 06
C H
Ph.
(041) 785 66 66
Fax (041) 785 66 33
C N
Ph.
(21) 58 68 21 19
Fax (21) 58 68 21 20
CZ
Ph.
(543) 25 25 05
Fax (543) 25 25 06
D K
Ph.
(44) 50 75 00
Fax (44) 50 75 75
E
Ph.
(93) 477 79 80
Fax (93) 477 79 81
EST
Ph.
(372)644 06 98
Fax (372)631 3 7 5 9
F
Ph.
(0388) 58 91 11
Fax (0388) 57 20 08
HKG
Ph.
24 80 12 02
Fax 24 18 19 45
I
Ph.
(02) 95 90 71
Fax (02) 95 90 72 51
IND
Ph.
(044)52 30 34 56
Fax (044)52 30 32 32
J
Ph.
(03) 53 05 36 10
Fax (03) 53 05 36 11
KOR
Ph.
(02) 34 62 55 92
Fax (02) 34 62 55 94
N
Ph.
(63) 84 44 10
Fax (63) 84 44 55
NL
Ph.
(0346) 58 10 10
Fax (0346) 56 37 17
NZ
Ph.
(09) 622 28 40
Fax (09) 622 28 47
P
Ph.
(21)212 84 90
Fax (21)212 84 91
PL
Ph.
(022) 840 60 10
Fax (022) 840 60 11
R C
Ph.
(02) 26 53 78 68
Fax (02) 26 53 79 68
RP
Ph.
(02) 776 43 8 4
Fax (02)776 43 82
S
Ph.
(040) 664 51 00
Fax (040) 664 51 01
SA
Ph.
(011)574 60 00
Fax (011) 454 14 77
SF
Ph.
(09) 54 97 06 00
Fax (09) 503 12 75
SIN
Ph.
68 44 22 33
Fax 68 44 35 32
TR
Ph.
(0232) 459 53 95
Fax (0232) 459 76 94
TT
Ph.
(04)643 50 08
Fax (04)643 70 10
U K
Ph.
(01453) 73 13 53
Fax (01453) 73 13 43
USA
Ph.
(949) 223 31 00
Fax (949) 223 31 98
Operating Instructions 0507/06_EU-ML_00804804

GENERAL NOTES

D
GB
These instructions explain with the aid of an example the
commissioning of a control head of Type 1066. A detailed
description of the device including the external connection of the
terminals, data bit allocation and LED displays can be found in the
operating instructions for the Type 1066.
Safety notes
• Keep to standard engineering rules in planning the use
of and operating the device!
• Installation and intervention for maintenance work are
only allowed by qualified personnel using suitable tools!
• Observe the current regulations on accident prevention
and safety for electrical devices!
• Before interfering with the system, always switch off the
voltage!
• Note that in systems under pressure, piping and valves
may not be loosened!
• Take suitable precautions to prevent inadvertent
operation or damage by unauthorized action!
• After interruption of the electrical or pneumatic supply,
make sure the process is restarted in a well-defined,
controlled manner!
EXERCISE CAUTION ON HANDLING!
ELECTROSTATICALLY SENSITIVE
COMPONENTS / MODULES
This device contains electronic components that are sensitive to
electrostatic discharge (ESD). Contact to electrostatically charged
persons or objects will endanger these components. In the worst
case, they will be immediately destroyed or will fail after
commissioning. Observe the requirements of EN 100 015 - 1 in
order to minimize the possibility of, or avoid, damage from
instantaneous electrostatic discharge. Also take care not to touch
electronic components that are under supply voltage.
GB
ATTENTION
GENERAL NOTES
Intended use
Please observe the notes in these operating instructions
together with the conditions of use and permitted data that are
specified on the rating plate in order that the device will function
perfectly and remain operable for a long time. On nonobser-vance of
these notes and unauthorized interference with the device, we will
refuse all liability and the warranty on device and accessories will
become void! The device serves exclusively as a positioner and
process control system. Any other use or use exceeding the specific
scope is considered to be non-intended use . Bürkert will not be
liable for any damage resulting therefrom. The risk will be borne by
the user.

TECHNICAL DATA

Operating conditions
Ambient temperature -10 to +50°C
Protection type
IP 67 to EN 60529
Electrical data
Supply voltage
24 V DC ± 10 %
(see rating plate)
24 / 110 / 230 V UC
or relevant field bus specification
Protection class
3 to VDE 0580
Pneumatic data
Control medium
Quality classes to DIN ISO 8573-1
- Dust content
max. particle size 40 µm
max. particle density 10 mg/m
- Water content
max. pressure dew point -20 °C
3
- Oil content
max. 25 mg/m
Temperatur range of
-10 to +50 °C
compressed air
Pressure range
2.5 to 7 bar
1)
Attention:Do not use industrial DC!
NOTE: All outputs fo the proximity switches are pnp plus
switching and short-circuit proof.
We reserve the right to make technical changes without notice!
GB
1)