AQUAPHOR RO-101S Manual do Proprietário - Página 4

Procurar online ou descarregar pdf Manual do Proprietário para Sistemas de filtragem de água AQUAPHOR RO-101S. AQUAPHOR RO-101S 20 páginas. Reverse osmosis system
Também para AQUAPHOR RO-101S: Manual do Proprietário (20 páginas), Manual do Proprietário (16 páginas)

AQUAPHOR RO-101S Manual do Proprietário
1. Operational parameters, Cont.
Table 1. The dependence of minimum necessary operating pressure of the water purifier from
mineralization.
Mineralization
mg/L, ppm
100.1
200.2
300.3
400.4
500.5
ATTENTION
The efficiency of RO depends on the incoming tap water mineralization and tap water pressure
(please see Table 1). The recommended operation of RO requires tap water pressure of at least
0.2 MPa (2 bar / 29.01 psi).
When tap water pressure is less than illustrated in the Table 1, it is highly recommended to
install a booster pump in order to obtain drainage ratio.

2. Safety instructions

Warning: RO must be applied to potable water only.
It is highly recommended that a water treatment specialist be hired to install and maintain this appliance.
When installing the appliance into a local water supply, it is recommended that you conduct a full water
analysis. If the water analysis does not correspond with the requirements, the life of the filtration and membrane
cartridges may be significantly reduced. In this case, it is recommended to use auxiliary water treatment sys-
tems (e.g. mechanical filter, de-ironing filter with, or alongside a water softener). Only use microbiological safe
water with your Reverse Osmosis system appliance.
Caution: Do not use water that is microbiologically unsafe or water of unknown quality without
adequate disinfection before or after using the appliance.
Caution: Reverse Osmosis water should not be run through copper tubing as the purity of the
water will leach copper and cause an objectionable taste in the water. Additionally, it will form
pinholes in the tubing. Be sure to follow any state or local regulations.
Caution: The Reverse Osmosis system is designed to be connected to cold water only. Never
run warm or hot water through your appliance.
4
gpg
MPa
5.8
0.2
11.7
0.25
17.5
0.3
23.4
0.4
29.2
0.6
Minimum pressure
bar
2
2.5
3
4
6
AQUAPHOR RO-101S, RO-102S
psi
29.01
36.26
43.51
58.02
87.02