3B SCIENTIFIC 1000540 Manual de instruções - Página 5
Procurar online ou descarregar pdf Manual de instruções para Instrumentos de medição 3B SCIENTIFIC 1000540. 3B SCIENTIFIC 1000540 8 páginas.
•
A small window will open so that you can
search for the driver software. Click "Find
driver software on this computer" in the
window.
•
Click "Select from a list of device drivers on
this computer".
•
Click the "Medium..." button.
•
Click the "Browse..." button and select the
path for the driver.
•
Click "Yes" to confirm that the file should
be overwritten.
7.2 Software installation
Note on installing the software
For this software, please refer to the installa-
tion instructions available in the 3B NETlab™
software manual.
8. Operating without a computer
Operating a 3B NETlog™ device without a
computer is achieved by using the buttons on
the operating panel. The functions of these
buttons may change according to the operation
being undertaken.
Note: a menu selection can be can-
celled at any time by using the
←
Channel
button.
8.1 Battery level and temperature display
•
Switch on the 3B NETlog™ device by
pressing the On/Off button.
Press the Date/Time ↵ button.
•
The following should appear on the display:
e.g.:
BATTERY: 100%
TEMP.: 22.0°C
8.2 Setting the time
•
Switch on the 3B NETlog™ device by
pressing the On/Off button.
Press the Date/Time ↵ button twice (the
•
time field will appear on the display).
Press the Store ↓ button (the input field for
•
SET TIME will appear on the display).
Specify the desired time in the input field
•
by pressing the Rate ↑ or the Store ↓ but-
ton and use the Channel ← button to skip
between the hours, minutes and seconds
fields.
Confirm by pressing the Date/Time ↵ but-
•
ton.
8.3 Setting the date
•
Switch on the 3B NETlog™ device by
pressing the On/Off button.
Press the Date/Time ↵ three times (the
•
date field will appear on the display).
Press the Store ↓ button (the input field for
•
SET DATE will appear on the display).
•
Specify the desired date in the input field
by pressing the Rate ↑ or Store ↓ button
and use the Channel ← button to skip be-
tween the year, month and day fields.
Confirm by pressing the Date/Time ↵ but-
•
ton.
8.4 Application as a handheld device for
measuring current and voltage
•
Set up the 3B NETlog™ equipment.
•
Connect the voltage/current input of chan-
nel A or B, as desired.
•
If necessary, disconnect any sensor which
might be connected to the same channel.
Setting and selecting measurement parame-
ters:
Press the Channel ← button (the menu
•
DISPLAY SIGNAL 1 will appear on the
display).
•
Select the desired measurement parame-
ter with the Rate ↑ or Store ↓ button.
•
Select the mode of operation with the
Date/Time ↵ button (the menu RANGE
SIGNAL 1 will appear on the display).
•
Select the desired mode of operation with
the Rate ↑ or Store ↓ button.
Confirm this selection with the Date/Time ↵
•
button (the menu DISPLAY SIGNAL 2 will
appear on the display).
•
Select the desired measurement parame-
ter with the Rate ↑ or Store ↓ button.
•
Select the desired mode of operation with
the Rate ↑ or Store ↓ button.
•
Confirm
the
Date/Time ↵ button (a dot will appear in
front of the respective measurement pa-
rameter when operating manually).
The 3B NETlog™ device is ready to conduct
measurements.
8.5 Application as a handheld measuring
device with sensors
•
Set up the 3B NETlog™ equipment.
•
Connect the sensor to the relevant input
and remove the connections of the 4-mm
sockets from the same channel.
5
selection
with
the