Operating Instructions and Parts Manual
Installation
When motor installation is within 5 ft.
(Continued)
(1.5 m) of the pool's interior walls, a
NOTE: Use an adhesive primer to
solid copper bonding conductor (mini-
ensure adhesive joints are secure.
mum size No. 8 AWG/8.4 mm
Suregard P-3000 has a purple tracer to
be connected from the accessible wire
qualify in areas where codes specify a
connector on the motor.
primer must be used.
• to all metal parts of the swimming
Consider climatic conditions when
pool
applying adhesives. Atmospheric condi-
• to all electrical equipment
tions with high humidity will make the
• to metal conduit
adhesive action of certain glues less
effective. Follow the manufacturer's
• to metal piping within 5 ft. (1.5 m)
instructions.
of the pool's interior walls
THREADED CONNECTIONS
IMPORTANT: Use copper
Use only Teflon
®
tape or equivalent on
conductors only.
threaded plumbing connections. Other
Refer to information on motor name-
pipe compounds may damage threads.
plate for electrical service data. Install
Do not use silicone or petroleum based
motors with a fused disconnect switch
compounds. Do not overtighten. Hand
or dedicated circuit breaker. Be sure
tightening plus 1/2 turn is sufficient.
wire size is sufficient for pump HP and
PUMP PLUMBING
distance from power source. Install a
ground fault circuit interrupter for
Suction pipe should be as large or larger
maximum safety.
than discharge pipe. Avoid using a suc-
tion pipe smaller than pump connection.
DANGER
1. Keep the piping as straight and
!
short as possible, and of suitable
source before attempting to install, ser-
size.
vice, relocate, or perform any mainte-
2. Do not connect an elbow directly
nance.
into the pump inlet. A length of
VOLTAGE SELECTOR
straight pipe will allow proper entry
This pump is factory wired for 230 volts.
of the water to the pump.
To change the voltage to 115 volts fol-
3. Slope horizontal runs upward to the
low the steps below:
pump to prevent trapping air.
1. Disconnect the pump from power.
4. Use independent piping supports to
2. Remove cover from back of motor
alleviate strain on the pump.
to find voltage selector (Figure 1a).
5. Keep as much of the suction line as
possible below the water level to
reduce priming time.
6. Install valves and unions in the
pump suction and return lines to
facilitate servicing. Valves will throt-
tle the pump discharge. Valves are
also essential for pump mainte-
nance if the system is installed
below deck level.
7. Use a check valve in the suction pipe
for inground pumps at or below the
water level if the suction lift is more
than 5 feet or the dry suction is
more than 10 feet long. Keep the
valve in the suction line fully open
during operation.
WIRING
WARNING
!
All
Figure 1a
wiring must be performed
by a qualified electrician.
The pump must be installed
3. Pull selector knob out.
in compliance with all local codes and
4. Rotate selector knob to correct volt-
the National Electrical Code.
age setting (Figure 1b).
115 Volts
115 Volts
2
) should
HI HI
LO
LO
LO
LO
Volt
Volt
Figure 1b
5. Push selector knob back in place.
6. Reinstall cover to back of motor.

Operation

Prime pump before attempting to oper-
ate. To prime pumps located above water
level, remove strainer cover, fill strainer
body with water then replace cover. If
pump and all piping is located below
water level, the pump will self prime.
After pump has been primed, open all
Disconnect, tag,
suction and discharge line valves and
and lock out power
energize motor. If no flow is observed
in five minutes, stop the motor and
reprime. If the pump fails to operate,
check for air leaks. Refer to trou-
bleshooting section.
After about 10 minutes of operation,
check the return fittings for air bubbles.
A continuous flow of air indicates leaks
in the suction line. Locate and correct
any leaks immediately.
CONTROLLING PUMP DISCHARGE
Keep the gate valve in the suction line
fully open during operation. To control
the discharge, use a valve in the return
line.
Do not retighten lid
L1
CAUTION
!
during operation.
Do not operate
CAUTION
!
pump with closed
suction or discharge valve.
WATER CHEMISTRY
Proper and consistent use of chemicals
is necessary to manage a water system.
Chlorine is the most commonly used
HI
LO
chemical to provide clean, sanitary
Volt
water. Daily administration of dry or
liquid chlorine (calcium or sodium
hypochlorite) is essential.
L2
IMPORTANT: Maintain the correct
level of acidity or alkalinity of the pool
water. Readings above pH 7.0 are alka-
line. A pH 7.0 is neutral. Readings
below pH 7.0 are acidic. A desirable
range is 7.2 to 7.4.
2
Manual de Instrucciones de Operación y Piezas
Para Piezas de Repuestos, Llame al 1-877-278-2797
230 Volts
230 Volts
4
HI HI
Volt
Volt
Notas
3
1
2
No. de
Ref.
Descripción
1
Juego de la bomba
2
Juego del sello del eje
3
Juego del motor
4
Tapa del cuerpo
de la bomba
5
Cesta filtrante
(no se muestra)
15 Sp
Envíe su solicitud de repuestos a la siguiente direccion:
AquaPro Systems
101 Production Drive
Harrison, OH 45030 U.S.A.
Sírvase proporcionar la suguiente información:
- Número de modelo
- Número de serie (si tiene)
- Descripción y número de repuesto como se muestra
en la lista de repuestos
WIP100PRO
WIP150PRO
Ctd.
69004-001
69005-001
1
21009-001
21009-001
1
69000-001
69001-001
1
28563-001
28564-001
1
28565-001
28566-001
1