AquaScape IONGEN SYSTEM G2 Manual de instruções - Página 8
Procurar online ou descarregar pdf Manual de instruções para Sistemas de filtragem de água AquaScape IONGEN SYSTEM G2. AquaScape IONGEN SYSTEM G2 20 páginas.
• Algae levels remain high after prolonged use
– Low copper level
Raise ionization level
– Insufficient water flow through Flow Chamber
In most of these cases the IonGen System will still produce a sufficient quantity of ions to kill the algae. If algae
levels are not being controlled move IonGen Probe to area of greater water flow. Plumbing into the water feature's
recirculating system is the most effective method.
– Scale build-up or debris suffocating IonGen Probe
In most of these cases the IonGen System will still produce a sufficient quantity of ions to kill the algae. If algae
levels are not being controlled move IonGen Probe to area of greater water flow. Plumbing into the water feature's
recirculating system is the most effective method.
– Water chemistry outside of targeted water parameters
See Targeted Water Parameters for Optimal Performance
– Algae type
The IonGen System is very effective at controlling filamentous string algae. Some types of algae are less affected by
copper ions than others. In these cases you may not have as noticeable results with the IonGen System.
Targeted Water Parameters for Optimal Performance
• To achieve the best results with the IonGen System it is recommended that the water feature's water is within the water
parameters listed below.
• The water feature's water parameters can change during the season, especially in features that experience high
evaporation. Many times a simple water change can help reset the water feature's water parameters.
• Alkalinity is an important parameter for the proper function of the IonGen System. One easy way to raise low alkalinity levels
is to use ordinary baking soda. Adding 1/4 cup (0.15 ponds) per 1,000 gallons will typically raise the alkalinity by 10 mg/L
(ppm). Raising the alkalinity should not be done all at once, but over a period of days. One easy way to lower high alkalinity
is performing a water change.
Copper: Less than 0.25 ppm
Alkalinity: 100-250 ppm
8
☎
☎
US (866) 877-6637 |
CAN (866) 766-3426 | aquascapeinc.com