Installing the Aquasteam In-Shower Temperature Probe
!
caution
The R emote Temperature Probe is for use with
Controls only. Do not use any other controls. Do not use any other temperature probe
aquasteam
with the
in-shower controls. Noncompatible products may result in
an inoperative control and a hazardous condition.
!
caution
Install the
installation and operation instructions. Failure to do so may result in
an inoperative control and a hazardous condition.
1. Determine the location of the R emote Temperature Probe.
The R emote Temperature Probe must be installed:
A. On a vertical surface
B . 4-5 ft. (1.2 - 1.5 m) above the floor
C. Away from the steam head
D. Not exposed to direct steam emis-
sion. The probe has an integral 30 ft.
(9.1 m) cable. Insure that the probe
and/or steam generator are located
accordingly. Contact a
technical service representative if a
longer cable is required.
IMPORTANT:
READ BEFORE LOCATING THE PROBE
DO NOT LOCATE THE PROBE NEAR OR
ABOVE THE STEAMHEAD AS THIS MAY
CAUSE DIRECT STEAM EMISSION TO
INTERFERE WITH STEAMROOM
TEMPERATURE REGULATION.
2. Drill a 5/16 inch (8 mm) diameter hole
in the wall as shown in Diagram 1.
Do not oversize or undersize the hole.
Clean area thoroughly.
3. R emove the knock-out from the
steam generator jacket as shown
in Diagram 2.
4. Insert the remote temperature
probe cable through the knock-out
and connect to the connector
onthe steam generator printed
circuit board marked "TE MP
PR OB E " as shown in Diagram 2.
For illustrative purposes only.
Note:
Consult with qualified designer,
architect or contractor for steam
room construction details.
10
aquasteam
control according to the
aquasteam
SteamGenerator
(shown with cover removes and NOT installed)
Temperature
Probe
Bad
Steam Head
n c h e s
6 - 1 2 I
c m )
( 1 5 - 3 0
Residential Steambath Generator Systems
aqua s tea m
in-shower controls.
Diagram 1
Printed Circuit
Board Component
shown for
illustrative purpose
Temp Probe
Knock-out
B
d a
4-5 Feet
(1.2-1.5 m)
Relation of Temperature Probe to Steamhead
Temperature
Sensing Probe
DRAWING NOT TO SCALE
Diagram 2
o G
d o
e B
t s
aquabrass.com