AQUASYSTEM KFC Series Manual de instruções - Página 6

Procurar online ou descarregar pdf Manual de instruções para Bomba de água AQUASYSTEM KFC Series. AQUASYSTEM KFC Series 10 páginas. Air driven motor drum can pump for acids, alkalis and solvents

AQUASYSTEM KFC Series Manual de instruções
INSPECTION
1. Check the air supply pressure
2. Make sure the pump has contact with liquid, which is going to be transferred
(running the pump in a constant dry state is strictly forbidden).
3. Make sure the air supply regulation valve is closed.
4. Use a ground wire for the pump and liquid container, if there is a risk of static
electricity.
USAGE
1.
Open the valve ④, insert device's suction pipe into the liquid.
2.
After making sure the air supply valve is closed, connect the air hose.
3.
Close the valve ④ and open the air supply valve. Then open the valve ④ gradually,
to adjust the delivery rate.
4.
After use, close the air supply valve and unplug the air supply hose. After that, open
[Valve ④ location is marked on the next page]
the valve ④.
TECHNICAL SPECIFICATIONS
Model
Max delivery rate
Max uplift (clear water)
Max temperature
Operated by
KFC103A-N
7.5m
AIR-DRIVEN MOTOR
Air pressure
Air consumption rate
Compressor power:
Connection
5
KFC104A-N
65L/min
8m
60℃
0.3~0.7Mpa
500Nl/min
For continuous operation:
5HP min. Otherwise: 3HP
Air hose φ8