Information You Will Need

Planning the Upgrade

2
Upgrading a VA 7100/7400 to a VA 7410/7110
In addition to this document, you will need the following information:
HP StorageWorks Virtual Array Installation Guide.
will be used when bringing the upgraded VA 7410/7110 back on line.
HP StorageWorks Virtual Array User and Service Guide
instruction for many of the hardware replacement procedures included in
the upgrade are included in this book.
These guides can be downloaded from the Manuals section of the following
web site:
http://www.hp.com/support/va7400
Quick Connect Guide(s)
documents provide detailed, operating system-specific configuration and
installation information. These guides can be downloaded from the
following internal HP web site:
http://hpso.rose.hp.com/spock/#NASL
Here are some things to consider when planning the upgrade:
Changing the physical configuration - because the entire array must be
powered off to perform the upgrade, this is an ideal time to move or
rearrange the array hardware components. This may be necessary if
additional disk enclosures are being added as part of the upgrade.
Note
The remaining items apply to the VA 7410 only.
Capacity requirements - the VA 7410 requires more disk capacity for
image disks. This additional capacity must be available on the array. If a
VA 7100 is being upgraded, the impact on available capacity may be
substantial because of the two redundancy groups used on the VA 7410.
Before upgrading a VA 7100, a careful assessment should be made of
how much additional capacity will be required on the array to create the
desired LUN configuration.
LUN configuration - when upgrading a VA 7400, the impact on the LUN
configuration will be minimal because the VA 7410 and VA 7400 both use
two redundancy groups. Upgrading a VA 7100 will have more impact
because the array is moving from one redundancy group to two. The LUN
Connectivity Streams Documents