HP StorageWorks 8/8 - SAN Switch Nota de lançamento
The error message is cryptic when the interop fabric contains more
than 60 devices in the default zone and the user tries cfgenablecfg-
disable.
When disabling/enabling a port, port fencing disables the port be-
cause the allowable number of invalid transmission words is exceeded.
Ag --show on an HP StorageWorks 8/8 or 8/24 SAN Switch shows
incorrect edge switch IP address after a slave port is swapped with
an N-port outside of the trunk group.
The 32-character switchname and chassisname extensions do not fully
display in RASLOG outputs, such as errdump or supportsave out-
put.
FFDC occurs when 16-31 char switch/chassis name is input on a
platform that only supports up to 15.
I2C response failure and subsequent reset occasionally results in HP
StorageWorks DC SAN Backbone Director fan fault errors.
Under some conditions N_Port Failover may not work when swapping
trunked and non-trunked N_Ports on an Access Gateway.
Auto_ELP setting for EX_Port is not restored by configdownload.
When running stressful IRNDUP to CUP tests, user may observe Inter-
mittent Channel Timeouts.
Warnings of excessively high temperature seen on some HP Storage-
Works 8/40 SAN switches.
POST (portloopback test) intermittently fails on HP StorageWorks
400 Multi-protocol Router and B-Series Multi-protocol Router blade.
Zone Transaction appears to succeed in SMIA when the transaction
was aborted by web GUI.
Port address from switchshow does not include offset used for Interop
mode 2.
32
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Reboot the switch and ag --show
cli will show the correct output.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use only 16-character switchname
and chassisname fields if full name
display in the logs is required.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Execute portdisable/porten-
able of F_Ports or switchdis-
able/switchenable or reboot the
switch.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use auto_elp mode.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Increase cooling or relocate switch to
cooler location. Be sure switch is in-
stalled with proper spacing above
and below it.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Rerun diags by rebooting the switch
or powering on the slot with B-Series
Multiprotocol Router blade.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.