Setting 0° Calibration
Note: The device is calibrated in the
factory for maximum accuracy.
User can re-calibrate if necessary.
1. Turn off the device and place it on
a flat, smooth surface.
2. While the device is still off,
press the ON/OFF and HOLD
buttons together until the display
reads "CAL".
3. Press the HOLD button again and
the display will now read "CAL1".
4. Without picking up the device,
rotate it 180° and press the HOLD
button again. The display will
now read "CAL2". The 0°
calibration is now complete.
180°
All manuals and user guides at all-guides.com
4840 Hytech Drive
Carson City
NV 89706 USA
1-775-885-4900
E-mail:
calculated.com
UG7434E-D
Inclination Icon
As shown in the drawings, the
inclination icon shows you in what
direction you need to move an object
to get to level. The direction is
measured relative to the right side of
the gauge.
If the short line is above the longer
line, the right side is high and needs to
be lowered. Note that the arrow points
down, the direction which the right side
of the gauge should be rotated.
If the short line is below the longer line,
the right side needs to be raised. Note
that the arrow points up, the direction
which the right side of the gauge
should be rotated.
One large line indicates level, 0.0° .
U
'
G
SER
S
UIDE
D
A
G
IGITAL
NGLE
AUGE
Model 7434 v1.1
SET 0