ARC MJLT-2005 Manual - Página 12

Procurar online ou descarregar pdf Manual para Controlo remoto ARC MJLT-2005. ARC MJLT-2005 20 páginas. Shutter remote control & receiver module

ARC MJLT-2005 Manual
Issue date: 29/7/2021
Set up with MJLT-2005
1. On the receiver module press SET button for 3 seconds, both LED on
module will flash.
2. With the remote press DOWN  button once to close the shutter and once it
reaches to the bottom, press the DOWN  button again. (Minimum level is
now stored)
3. Press UP  button once to open the shutter and once it reaches to the top,
press the UP  button again. (Maximum level is now stored)
4. To complete the set-up mode, press SET button on receiver module for 3
seconds, both LED on module will quick flash to confirm.
 If no signal is given within the 30 second time frame, the receiver will exit
the set-up mode.)
Set up with LYCT-505
1. Make sure the receiver module is first paired with the remote control and
with the shutter at top (open) position.
2. On the receiver module press SET button for 3 seconds, both LED on
module will flash.
3. With the remote press OFF button to close the shutter and once it reaches to
the bottom, press the OFF button again. (Minimum level is now stored)
4. Press ON button to open the shutter and once it reaches to the top, press
the ON button again. (Maximum level is now stored)
5. To complete the set-up mode, press SET button on receiver module for 3
seconds, both LED on module will quick flash to confirm.
 If no signal is given within the 30 second time frame, the receiver will exit
the set-up mode.)
In case the shutter level is not in the right position after few usages, you can
manually calibrate the shutter by letting the shutter reach to the top or bottom
(maximum or minimum level) and wait for 2 minutes.
MOTOR CALIBRATION