ARC MJLT-2005 Manual - Página 11

Procurar online ou descarregar pdf Manual para Controlo remoto ARC MJLT-2005. ARC MJLT-2005 20 páginas. Shutter remote control & receiver module

ARC MJLT-2005 Manual
Issue date: 29/7/2021
There are wide variety of shutters, curtains, and motorised electronics in the
market. So, for a better performance the receiver module has a calibration
features built in.
For the shutter to position properly, we must firstly set up the maximum and
minimum level of the actual shutter you wish to control.
Carefully follow the below procedure with each individual receiver modules.
Set up within receiver module
1. On the receiver module press SET button for 3 seconds, both LED on
module will flash.
2. Press DOWN  button once to close the shutter and once it reaches to the
bottom, press the DOWN  button again. (Minimum level is now stored)
3. Press UP  button once to open the shutter and once it reaches to the top,
press the UP  button again. (Maximum level is now stored)
4. To complete the set-up mode, press SET button for 3 seconds, both LED on
module will quick flash to confirm.
 If no signal is given within the 30 second time frame, the receiver will exit
the set-up mode.)

MOTOR CALIBRATION

7. Motor Calibration
11