4. A dual position cable clamp is provided.
For top cable entry use retaining bar in horizontal position supplied.
For bottom cable entry rotate retaining bar to the angled position.
d) FINAL INSTALLATION PROCEDURE AND COMMISSIONING
WARNING: DO NOT SWITCH ON THE ELECTRICITY SUPPLY UNTIL THE FOLLOWING
PROCEDURE HAS BEEN COMPLETED. FAILURE TO DO SO COULD CAUSE
THE PUMP TO RUN DRY AND INVALIDATE THE GUARANTEE
1. Fit the front cover back into position, ensuring that both the control knobs are correctly aligned
with the flow valve and power selector. Secure with top and bottom screws.
2. Fit hose and prime the shower first without the handset to flush out any remaining debris. To
prime the shower, ensure that the electricity supply is turned off. Turn control knob "B" fully
anticlockwise. Water should start to flow with motor switched off allowing all the air to be purged
out of the shower unit.
It may be necessary to lower the hose below the level of the shower whilst priming.
Stop water flow by turning control knob "B" fully clockwise. Attach handset, switch on electrical
supply and then operate the shower as on page 7 and check:-
a. That the water gets to a satisfactory temperature.
b. Water flow can be adjusted by control knob "B".
c. Power selection operates in both positions, giving a change in water temperature.
d. Check again for leaks.
e. That the holes in the shower handset are not blocked.
f. That the motor turns off and water stops flowing in the "Stop" position.
3. DEMONSTRATE OPERATION TO USERS
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN)
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use
of abrasive or solvent based cleaning fluid be avoided, especially on any plated finishes.
We recommend that before any cleaning, the isolating switch be turned off, thus avoiding
accidentally switching on the shower.
WARNING: YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR AND DAMAGE.
REPLACE IF NECESSARY, OR EVERY TWO YEARS, WITH AN APPROVED PART.
WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,
YOU MUST CLEAN THE SHOWER HANDSET REGULARLY
All water contains particles of lime-scale, which build up in the shower handset and
unit reducing the performance.
It is therefore important to clean the shower handset by simply rubbing the rubber
nozzles, or soaking in proprietary lime-scale remover, rinsing thoroughly before use.
NOTE: After use it is normal for some water to drip from the shower handset for
a few moments. This inhibits scale build-up over prolonged use.
IMPORTANT WARNINGS!
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
DO NOT PLAY WITH THE APPLIANCE.
HOW TO MAINTAIN YOUR CREDA SHOWER
6